Two-dimensional arrays for medical ultrasound using multilayer flexible circuit interconnection
- 1 March 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 45 (2) , 338-348
- https://doi.org/10.1109/58.660144
Abstract
The development of 2-D array transducers has received much recent interest. Unfortunately, fabrication of high density 2-D arrays is difficult due to the large number of electrical interconnections which must be made to the back side of the elements. A typical array operating at 2.2 MHz may have 256 or more connections within a 16.4 mm circular footprint. Interconnection becomes even more challenging as operating frequencies increase. To solve this problem, we have developed a multilayer flexible (MLF) circuit interconnect consisting of a polyimide dielectric with inter-laminar vias routing signals vertically and etched metal traces routing signals horizontally. A transducer is fabricated from an MLF by bonding a PZT chip to its surface and dicing the chip into individual elements, with the saw kerf extending partially into the top polyimide layer to ensure physical and electrical isolation of the elements. The KLM model was used to compare the performance of an MLF 2-D array to a conventional hand wired 2-D array. MLF and wire guide transducers were fabricated, each with 256 active elements, 0.4 mm interelement spacing, and 2.2 MHz center frequency. Vector impedance, pulse length, bandwidth, angular response, and cross-coupling were found to be comparable in both types of arrays. Using the MLF, however, fabrication time was reduced dramatically. More importantly, MLF technology may be used to increase 2-D array connection density beyond the limitations of current of hand wired fabrication techniques. Thus MLF circuits provide a means for the interconnection of current and future high frequency 2-D arrays.Keywords
This publication has 18 references indexed in Scilit:
- Applications of microelectronics and microfabrication to ultrasound imaging systemsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- A 2.5 MHz 2D array with Z-axis backingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Simulation of B-scan images from two-dimensional transducer arraysPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- A 128×4 channels 1.5D curved linear array for medical imagingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Two-dimensional array transducers using thick film connection technologyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1993
- Electromechanical modeling using explicit time-domain finite elementsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1993
- A novel method for angle independent ultrasonic imaging of blood flow and tissue motionIEEE Transactions on Biomedical Engineering, 1991
- Experimental results with a real-time adaptive ultrasonic imaging system for viewing through distorting mediaIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1990
- Simulation of piezoelectric devices by two- and three-dimensional finite elementsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1990
- Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principlesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1988