Second Coordinate Readout in Drift Chambers by Charge Division
- 1 February 1978
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 25 (1) , 46-52
- https://doi.org/10.1109/tns.1978.4329274
Abstract
The drift time measurement and the charge division can be performed simultaneously on the same electrode (resistive anode) without affecting the accuracy of either measurement. It is shown that for the shortest measurement time there is an optimum value for the anode wire resistance. The signal requirement for a position uncertainty σ≤ 0.5% of the anode wire length is only 2.7 x 106 electron charges. The drift chamber can be operated in the linear mode and with negligible space charge effects, so that it can also be used for ΔE/ΔX measurements. A simple preamplifier optimized for both the time and charge measurements using a monolithic transistor array is described.Keywords
This publication has 8 references indexed in Scilit:
- A Two-Dimensional Drift ChamberIEEE Transactions on Nuclear Science, 1977
- Flat Helical Delay Lines for Position Readout along the Anode Wire in MWPC and Drift ChambersIEEE Transactions on Nuclear Science, 1977
- Large proportional multiwire chambers for transition radiation detection with unambiguous position readoutNuclear Instruments and Methods, 1976
- Position Sensing by Charge DivisionIEEE Transactions on Nuclear Science, 1976
- Low mass cylindrical multiwire proportional chamber with unambiguous dual coordinate readoutNuclear Instruments and Methods, 1975
- A two-dimensional position-sensitive detector for thermal neutronsNuclear Instruments and Methods, 1975
- Printed Low Velocity Delay Lines for Cathode Readout of Proportional ChambersIEEE Transactions on Nuclear Science, 1975
- Signal, Noise and Resolution in Position-Sensitive DetectorsIEEE Transactions on Nuclear Science, 1974