Optic nerve sonography in the diagnostic evaluation of adult brain injury
Top Cited Papers
Open Access
- 13 May 2008
- journal article
- research article
- Published by Springer Nature in Critical Care
- Vol. 12 (3) , R67
- https://doi.org/10.1186/cc6897
Abstract
Introduction: The optic nerve sheath diameter (ONSD) may be increased in brain-injured patients, especially children, with intracranial hypertension. We investigated whether measurements of ONSD correlated with simultaneous noninvasive and invasive measurements of the intracranial pressure (ICP) in brain-injured adults. Methods: Seventy-six critical care patients (58 males; 47 ± 18 years old) were included in the study. Fifty patients suffered from brain injury, whereas 26 had no intracranial pathology and served as control individuals. Initially, brain-injured patients were evaluated clinically (Glasgow Coma Scale) and using a semiquantitative (I to VI) neuroimaging scale (Marshall Scale). Thereafter, the patients were divided into those with moderate (Marshall Scale = I and Glasgow Coma Scale > 8 [n = 18]) and severe (Marshall Scale = II to VI and Glasgow Coma Scale ≤8 [n = 32]) brain injury. All patients underwent noninvasive measurement of the ICP (estimated ICP) by transcranial Doppler sonography, and synchronous ONSD measurements by optic nerve sonography. Finally, invasive ICP measurement using an intraparenchymal catheter was performed in patients with severe brain injury. Results: ONSD and estimated ICP were both significantly increased (6.1 ± 0.7 mm and 26.2 ± 8.7 mmHg, respectively; P < 0.0001) in patients with severe brain injury as compared with patients with moderate brain injury (4.2 ± 1.2 mm and 12.0 ± 3.6 mmHg) and compared with control individuals (3.6 ± 0.6 mm and 10.3 ± 3.1 mmHg). Furthermore, in patients with severe brain injury the ONSD measurements were strongly correlated with estimated ICP values (r = 0.80, P < 0.0001) as well as with the neuroimaging scale results (r = 0.82, P < 0.001). In the patients with severe brain injury, ONSD measurements correlated with invasive ICP values (r = 0.68, P = 0.002). The best cut-off value of ONSD for predicting elevated ICP was 5.7 mm (sensitivity = 74.1% and specificity = 100%). Conclusion: ONSD measurements correlate with noninvasive and invasive measurements of the ICP, and with head computed tomography scan findings in brain-injured adults. Hence, optic nerve sonography may serve as an additional diagnostic tool that could alert clinicians to the presence of elevated ICP, whenever invasive ICP evaluation is contraindicated and/or is not available. This trial is International Standard Randomised Controlled Trial Number registered (ISRCTN 91941687).Keywords
This publication has 39 references indexed in Scilit:
- Emergency Department Sonographic Measurement of Optic Nerve Sheath Diameter to Detect Findings of Increased Intracranial Pressure in Adult Head Injury PatientsAnnals of Emergency Medicine, 2007
- Clinical applications of a non-invasive ICP monitoring methodEuropean Journal of Ultrasound, 2002
- Perioperative Head Injury Management in the Multiply Injured Trauma PatientInternational Anesthesiology Clinics, 2002
- Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertensionPediatric Radiology, 1996
- Statistics Notes: Correlation, regression, and repeated dataBMJ, 1994
- Transcranial doppler recordings in raised intracranial pressureActa Neurologica Scandinavica, 1993
- The effect of changes in cerebral perfusion pressure upon middle cerebral artery blood flow velocity and jugular bulb venous oxygen saturation after severe brain injuryJournal of Neurosurgery, 1992
- Echographic correlation of optic nerve sheath size and cerebrospinal fluid pressure.1989
- Echographic measurement of the optic nerve in patients with intracranial hypertensionmin - Minimally Invasive Neurosurgery, 1987
- A transcranial Doppler method in the evaluation of cerebrovascular spasmNeuroradiology, 1986