Factors affecting error in integration of electroanatomic mapping with CT and MR imaging during catheter ablation of atrial fibrillation
- 25 January 2007
- journal article
- clinical trial
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 17 (1) , 21-27
- https://doi.org/10.1007/s10840-006-9060-2
Abstract
Integration of 3-D electroanatomic mapping with Computed Tomographic (CT) and Magnetic Resonance (MR) imaging is gaining acceptance to facilitate catheter ablation of atrial fibrillation. This is critically dependent on accurate integration of electroanatomic maps with CT or MR images. We sought to examine the effect of patient- and technique-related factors on integration accuracy of electroanatomic mapping with CT and MR imaging of the left atrium. Sixty-one patients undergoing catheter-based atrial fibrillation (AF) ablation procedures were included. All patients underwent cardiac CT (n = 11) or MR (n = 50) imaging, and image integration with real-time electroanatomic mapping of the aorta and left atrium (LA). CARTO-Merge software (Biosense-Webster) was used to calculate the overall average accuracy of integration of electroanatomic points with the CT and MR-derived reconstructions of the LA and aorta. There was a significant correlation between LA size assessed by electroanatomic mapping (112 +/- 31 ml) and average integration error (1.9 +/- 0.6 mm) (r = 0.46, p = 0.0003). There was also greater integration error for patients with LA volume >/= 110 ml (n = 31) versus < 110 ml (n = 30) (p = 0.004). In contrast, there was no significant association between average integration error and paroxysmal versus persistent AF, left ventricular ejection fraction, days from imaging to electroanatomic mapping, or images derived from CT versus MR. Patients with larger LA volume may be prone to greater error during integration of electroanatomic mapping with CT and MR imaging. Strategies to reduce integration error may therefore be especially useful in patients with large LA volume.Keywords
This publication has 17 references indexed in Scilit:
- Three‐Dimensional Anatomy of the Left Atrium by Magnetic Resonance Angiography: Implications for Catheter Ablation for Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Robotic Magnetic Navigation for Atrial Fibrillation AblationJournal of the American College of Cardiology, 2006
- Integrated Electroanatomic Mapping With Three-Dimensional Computed Tomographic Images for Real-Time Guided AblationsCirculation, 2006
- Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation proceduresHeart Rhythm, 2005
- Efficacy and Safety of Segmental Ostial Versus Circumferential Extra‐Ostial Pulmonary Vein Isolation for Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2004
- Assessment of Pulmonary Vein Anatomic Variability by Magnetic Resonance Imaging:Journal of Cardiovascular Electrophysiology, 2004
- Initial Experience With Remote Catheter Ablation Using a Novel Magnetic Navigation SystemCirculation, 2004
- Catheter Ablation for Paroxysmal Atrial FibrillationCirculation, 2003
- Catheter Ablation of Paroxysmal Atrial Fibrillation Using a 3D Mapping SystemCirculation, 1999
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998