Electroosmotic Flow in Composite Microchannels and Implications in Microcapillary Electrophoresis Systems
- 20 January 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (4) , 829-836
- https://doi.org/10.1021/ac0011181
Abstract
The electroosmotic flow in laminated excimer laser-ablated microchannels has been studied as a function of the depth of the rectangular channels, and particular emphasis has been given to the difference in the ζ-potentials between the lamination layer and the ablated substrate. Experimental electroosmotic flow follows the tendency predicted by a recently published model. The ζ-potentials of lamination and ablated surfaces were determined for poly(ethylene terephthalate) and poly(carbonate) substrates by fitting the experimental data with a numerical implementation of this model. In the experimentally investigated range of channel cross sections, a linear fit to the data gives a good approximation of the ζ-potentials for both materials. Moreover, a flow injection analysis of fluorescein dye has been performed to show the severe loss in numbers of theoretical plates, caused by Taylor dispersion, when such microchannels, dedicated to microcapillary electrophoresis, are used.Keywords
This publication has 22 references indexed in Scilit:
- Finite Element Simulation of an Electroosmotic-Driven Flow Division at a T-Junction of Microscale DimensionsAnalytical Chemistry, 2000
- Topography, Crystallinity and Wettability of Photoablated PET SurfacesLangmuir, 1999
- Design and development of a miniaturised total chemical analysis system for on-line lactate and glucose monitoring in biological samplesAnalytica Chimica Acta, 1997
- UV Laser Machined Polymer Substrates for the Development of Microdiagnostic SystemsAnalytical Chemistry, 1997
- Development and Operating Characteristics of Micro Flow Injection Analysis Systems Based on Electroosmotic FlowA ReviewThe Analyst, 1997
- Ultra-High-Speed DNA Sequencing Using Capillary Electrophoresis ChipsAnalytical Chemistry, 1995
- Fused Quartz Substrates for Microchip ElectrophoresisAnalytical Chemistry, 1995
- Electroosmotic Pumping and Valveless Control of Fluid Flow within a Manifold of Capillaries on a Glass ChipAnalytical Chemistry, 1994
- Glass chips for high-speed capillary electrophoresis separations with submicrometer plate heightsAnalytical Chemistry, 1993
- Ultrasonic absorption of aqueous binary mixtures. 3. Tetrahydrofuran-water at 25.degree.CThe Journal of Physical Chemistry, 1981