Correlation of preoperative factors, severity of disease, type of oxygenator and perfusion times with mortality and morbidity of coronary bypass
- 1 January 1991
- journal article
- other
- Published by SAGE Publications in Perfusion
- Vol. 6 (1) , 15-22
- https://doi.org/10.1177/026765919100600103
Abstract
Previous studies have related preoperative status and severity of disease to the outcome of coronary artery bypass surgery. Although increased perfusion and clamp times increase the risk of cardiac surgical procedures, the importance of these factors in relation to the patient's preoperative condition and the severity of disease has not previously been determined. In this study of 1078 patients, we examined the correlation between the patient's preoperative condition, the severity of coronary disease, and duration of perfusion and clamp time, and the type of oxygenator used with the mortality and morbidity associated with coronary artery bypass grafting. One-way analysis of variance and multiple correlation analysis showed that perfusion time, clamp time and nonclamp perfusion time correlated with mortality, perioperative infarction, the use of intra-aortic balloon pump, stroke, renal failure, pulmonary failure, infection, and leg wound complications (p < 0.05). Perfusion time, clamp time and nonclamp perfusion time did not correlate with postoperative bleeding or sternal wound complications. Nonclamp perfusion time correlated more strongly than any other factor with mortality, perioperative infarction, the use of intra-aortic balloon pump, renal failure, pulmonary failure and infection (p < 0.05). Clamp time correlated more than any other factor with the development of leg-wound complications (p < 0.05). The use of a bubble rather than a membrane oxygenator was significantly related to mortality, stroke, infection and leg wound complications by one-way analysis of variance (p < 0.05). The results of this study suggest that increased duration of nonclamp perfusion time and clamp time, combined with the use of a bubble oxygenator, increases the risk of mortality and morbidity for coronary artery bypass grafting.Keywords
This publication has 19 references indexed in Scilit:
- Correlates of total perfusion time, clamp time and nonclamp perfusion time in coronary bypass surgeryPerfusion, 1989
- Preoperative Left Ventricular Dysfunction and Operative Risks in Coronary Bypass SurgeryChest, 1987
- Preoperative Risk Assessment in Cardiac Surgery: Comparison of Predicted and Observed ResultsThe Annals of Thoracic Surgery, 1987
- Determination of Body Mass IndexPublished by American Medical Association (AMA) ,1986
- Stroke Following Coronary Artery Bypass Grafting: A Ten-Year StudyThe Annals of Thoracic Surgery, 1985
- Health Implications of ObesityAnnals of Internal Medicine, 1985
- Clinical and angiographic predictors of operative mortality from the collaborative study in coronary artery surgery (CASS).Circulation, 1981
- Perioperative Myocardial Infarction in Coronary Artery Bypass SurgeryThe Thoracic and Cardiovascular Surgeon, 1980
- Alterations of Hemostasis Associated With Cardiopulmonary Bypass: Pathophysiology, Prevention, Diagnosis, and ManagementSeminars in Thrombosis and Hemostasis, 1976
- Acute postoperative renal failure in cardiac surgical patientsJournal of Surgical Research, 1976