OUTCOMES FOLLOWING REVISIONS AND SECONDARY IMPLANTATION OF THE ARTIFICIAL URINARY SPHINCTER
- 1 April 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 173 (4) , 1242-1245
- https://doi.org/10.1097/01.ju.0000152315.91444.d0
Abstract
Durable success with the artificial urinary sphincter (AUS) is common but device revision and replacement are often needed for various reasons. We examined indications and outcomes following these secondary procedures with comparisons to outcomes after primary procedures. The medical records of all patients undergoing primary and secondary bulbar urethral AUS implantation and revision from January 1990 to September 2002 were reviewed for various demographic and surgical variables. Female patients and males with bladder neck cuffs were excluded from study. Of 554 men undergoing AUS implantation or revision 119 (21.4%) underwent a total of 159 secondary procedures. Reasons for revision were mechanical failure in 31 cases (25.2%) and nonmechanical failure in 88 (73.9%). The latter included recurrent incontinence due to urethral atrophy in 63 cases (52.9%) and erosion in 21 (17.6%). Total device replacement was performed in 75 cases (47.2%). Of 119 patients undergoing secondary implantation 91 (76.5%) needed no additional surgical intervention, while 28 (23.5%) required a total of 40 surgical revisions for new mechanical (15 or 37.5%) and nonmechanical (25 or 62.5%) problems. Five-year durability outcomes for primary and secondary AUS implantation were comparable at 80% and 88%, respectively. Similarly excellent continence outcomes (0 to 1 pad daily) were noted in 90% and 82% of patients undergoing primary and secondary AUS implantation, respectively. Secondary and tertiary AUS revisions resulted in the restoration of baseline continence in 106 cases (89%). Our study suggests that outcomes for secondary AUS reimplantation are comparable to those of primary AUS implantation and salvage of a good outcome is always probable, even following multiple prior revisions and cuff erosion.Keywords
This publication has 20 references indexed in Scilit:
- Urethral Atrophy After Artificial Urinary Sphincter Placement: Is Cuff Downsizing Effective?Journal of Urology, 2003
- A National Survey Of Urinary And Health Related Quality Of Life Outcomes In Men With An Artificial Urinary Sphincter For Post-Radical Prostatectomy IncontinenceJournal of Urology, 2003
- LONG-TERM CONTINENCE AND PATIENT SATISFACTION AFTER ARTIFICIAL SPHINCTER IMPLANTATION FOR URINARY INCONTINENCE AFTER PROSTATECTOMYJournal of Urology, 2001
- THE LONG-TERM OUTCOME OF ARTIFICIAL URINARY SPHINCTERSJournal of Urology, 2000
- SUCCESS OF DE NOVO REIMPLANTATION OF THE ARTIFICIAL GENITOURINARY SPHINCTERJournal of Urology, 2000
- MAYO CLINIC LONG-TERM ANALYSIS OF THE FUNCTIONAL DURABILITY OF THE AMS 800 ARTIFICIAL URINARY SPHINCTER: A REVIEW OF 323 CASESJournal of Urology, 1998
- Quality of Life and Continence Assessment of the Artificial Urinary Sphincter in Men With Minimum 3.5 Years of FollowupJournal of Urology, 1997
- Successful reinsertion of the artificial urinary sphincter after removal for erosion or infectionUrology, 1996
- Proximal artificial sphincter cuff repositioning for urethral atrophy incontinenceUrology, 1995
- Artificial urinary sphincter cuff erosionexperience with reimplantation in 38 patientsUrology, 1990