Morphometric evaluation of subaxial cervical spine using multi-detector computerized tomography (MD-CT) scan: the consideration for cervical pedicle screws fixation
Open Access
- 11 April 2014
- journal article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 125
- https://doi.org/10.1186/1471-2474-15-125
Abstract
Background Cervical pedicle screw (CPS) insertion is a technically demanding procedure. The quantitative understanding of cervical pedicle morphology, especially the narrowest part of cervical pedicle or isthmus, would minimize the risk of catastrophic damage to surrounding neurovascular structures and improve surgical outcome. The aim of this study was to investigate morphology and quantify cortical thickness of the cervical isthmus by using Multi-detector Computerized Tomography (MD-CT) scan. Methods The cervical CT scans were performed in 74 patients (37 males and 37 females) with 1-mm slice thickness and then retro-reconstructed into sagittal and coronal planes to measure various cervical parameters as follows: outer pedicle width (OPW), inner pedicle width (IPW), outer pedicle height (OPH), inner pedicle height (IPH), pedicle cortical thickness, pedicle sagittal angle (PSA), and pedicle transverse angle (PTA). Results Total numbers of 740 pedicles were measured in this present study. The mean OPW and IPW significantly increased from C3 to C7 while the mean OPH and IPH of those showed non-significant difference between any measured levels. The medial-lateral cortical thickness was significantly smaller than the superior-inferior one. PTA in the upper cervical spine was significantly wider than the lower ones. The PSA changed from upward inclination at upper cervical spine to the downward inclination at lower cervical spine. Conclusions This study has demonstrated that cervical vertebra has relatively small and narrow inner pedicle canal with thick outer pedicle cortex and also shows a variable in pedicle width and inconsistent transverse angle. To enhance the safety of CPS insertion, the entry point and trajectories should be determined individually by using preoperative MD-CT scan and the inner pedicle width should be a key parameter to determine the screw dimensions.Keywords
This publication has 31 references indexed in Scilit:
- Intraoperative, full-rotation, three-dimensional image (O-arm)–based navigation system for cervical pedicle screw insertionJournal of Neurosurgery: Spine, 2011
- 3D-based navigation in posterior stabilisations of the cervical and thoracic spine: problems and benefits. Results of 451 screwsEuropean Journal of Trauma and Emergency Surgery, 2011
- The Impact of Cervical Pedicle Screws for Primary Stability in Multilevel Posterior Cervical StabilizationsSpine, 2010
- Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengthsThe Spine Journal, 2006
- Complications of Pedicle Screw Fixation in Reconstructive Surgery of the Cervical SpineSpine, 2000
- Posterior Occipitocervical Reconstruction Using Cervical Pedicle Screws and Plate–Rod SystemsSpine, 1999
- Cervical Pedicle Screws Versus Lateral Mass ScrewsSpine, 1997
- Biomechanical Analysis of Cervical Stabilization SystemsSpine, 1994
- Transpedicular Screw Fixation for Traumatic Lesions of the Middle and Lower Cervical SpineJournal of Spinal Disorders, 1994
- Anatomic Considerations for Plate-Screw Fixation of the Cervical SpineSpine, 1991