Abstract
The ADVIA 120/2120 Hematology System provides a number of novel parameters of platelet activation. Although the effects of anticoagulant in the blood-collection tube, short-term storage, and ambient temperature on these parameters have been documented in the literature, the effects of long-term storage and the material of the blood-draw tube have not been investigated. We therefore compared platelet activation parameter values obtained with the ADVIA 120 for 50 paired blood samples collected into BD Medical Systems' Vacutainer K(3)EDTA glass tubes and Vacutainer K(2)EDTA Plus plastic tubes and analyzed within 4 hours and after 24 hours following venipuncture. We found a statistically significant but clinically irrelevant decrease (less than 1%) in mean platelet component (MPC) concentration in plastic compared with glass for blood samples analyzed within 4 hours of draw. Reanalysis of the samples after 24 hours showed a clinically and statistically significant increase in mean platelet volume and significant decreases in MPC, platelet component distribution width, and mean platelet mass. These storage-induced changes were of equal magnitude for both tube types. We conclude that the use of plastic versus glass blood-draw tubes should have no clinically significant effect on the parameters of platelet activation on the ADVIA 120/2120 system and that the changes in platelet activation parameters continue to be present at 24 hours.Keywords
This publication has 9 references indexed in Scilit:
- Comparison of Five Different Citrated Tubes and Their in Vitro Effects on Platelet ActivationClinical Chemistry, 2004
- Assessment of platelet activation in several different anticoagulants by the Advia 120 Hematology System, fluorescence flow cytometry, and electron microscopyThrombosis and Haemostasis, 2003
- Ethylenediaminetetraacetic acid plus citrate‐theophylline‐adenosine‐dipyridamole (EDTA‐CTAD): A novel anticoagulant for the flow cytometric assessment of platelet and neutrophil activation ex vivo in whole bloodCytometry Part B: Clinical Cytometry, 2002
- Evaluation of platelet parameters on the ADVIA 120 as the quality indicator for stored plateletsClinical and Laboratory Haematology, 2002
- Platelet count and parameters determined by the Bayer ADVIATM 120 in reference subjects and patientsClinical and Laboratory Haematology, 2001
- Improved Platelet Counting Using Two-Dimensional Laser Light ScatterAmerican Journal of Clinical Pathology, 2000
- The determination of a reference range for new platelet parameters produced by the Bayer ADVIATM 120 full blood count analyserClinical and Laboratory Haematology, 2000
- Use of mean platelet component to measure platelet activation on the ADVIA 120 haematology systemCytometry, 1999
- A Technique for Estimating the Probability of Clots in Blood/ Contrast Agent MixturesInvestigative Radiology, 1988