Analysis of noise effects on DTI‐based tractography using the brute‐force and multi‐ROI approach
Open Access
- 23 August 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (3) , 559-565
- https://doi.org/10.1002/mrm.20147
Abstract
Diffusion tensor tractography based on line propagation is a promising and widely used technique, but it is known to be sensitive to noise and the size and location of the seed regions of interest (ROIs). The effects of these parameters on the tractography results were analyzed quantitatively using high‐resolution diffusion tensor imaging (DTI) with a high signal‐to‐noise ratio (SNR) on a fixed mouse brain. The anterior commissure (AC), as judged from a T2‐weighted image, was used as an anatomical reference within which the tracts could be located. Monte Carlo simulation was performed by adding Gaussian noise to the time domain data and repeating the tractography. Deviations of the tracking results were measured as a function of SNR. Such noise effects were evaluated for a simple one‐ROI approach and a combined two‐ROI and brute‐force (BF) approach. The influence of ROI size and location for the two‐ROI + BF approach was also analyzed. The results confirmed the hypothesis that one can increase the validity of DTI‐based tractography by adopting the BF and multi‐ROI approach, with respect to the simple one‐ROI approach. Magn Reson Med 52:559–565, 2004.Keywords
This publication has 28 references indexed in Scilit:
- Spatial normalization of diffusion tensor fieldsMagnetic Resonance in Medicine, 2003
- The basis of anisotropic water diffusion in the nervous system – a technical reviewNMR in Biomedicine, 2002
- Fiber tracking: principles and strategies – a technical reviewNMR in Biomedicine, 2002
- Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical reviewNMR in Biomedicine, 2002
- Diffusion tensor fiber tracking of human brain connectivity: aquisition methods, reliability analysis and biological resultsNMR in Biomedicine, 2002
- Spatial Normalization and Averaging of Diffusion Tensor MRI Data SetsNeuroImage, 2002
- Validation of Diffusion Tensor Magnetic Resonance Axonal Fiber Imaging with Registered Manganese-Enhanced Optic TractsNeuroImage, 2001
- Spatial transformations of diffusion tensor magnetic resonance imagesIEEE Transactions on Medical Imaging, 2001
- Toward a quantitative assessment of diffusion anisotropyMagnetic Resonance in Medicine, 1996
- Anisotropy of NMR properties of tissuesMagnetic Resonance in Medicine, 1994