Vicarious radiometric calibration of eo-1 sensors by reference to high-reflectance ground targets
- 11 August 2003
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 41 (6) , 1174-1179
- https://doi.org/10.1109/tgrs.2003.813211
Abstract
The Remote Sensing Group at the University of Arizona has been using ground targets for the in-flight vicarious calibration of airborne and satellite sensors since the early 1980s. Targets such as Railroad Valley Playa in north central Nevada and White Sands Missile Range in New Mexico have proven to be useful for this work. This paper presents the results from multiple vicarious calibration experiments at a variety of sites for two of the Earth Observing 1 (EO-1) optical sensors. The Advanced Land Imager (ALI) and Hyperion sensors operate in the visible and shortwave infrared portions of the spectrum. The ground sample distance of about 30 m works well for vicarious calibration and allows an easy comparison to legacy sensors such as the Enhanced Thematic Mapper Plus (ETM+) which has the same 30-m ground sample distance. The approach used in this work is to measure the surface reflectance and atmospheric properties during the sensor image acquisition. These data are used as input to a radiative transfer code which computes the top of atmosphere spectral radiance. This predicted radiance is compared to the radiance from the image of the site. Results show that the preflight calibrations of ALI and Hyperion are probably not consistent with in-flight performance of the instruments. New calibration coefficients adopted in December 2001 improve the comparison to the vicarious predictions.Keywords
This publication has 6 references indexed in Scilit:
- Absolute radiometric calibration of Landsat 7 ETM+ using the reflectance-based methodRemote Sensing of Environment, 2001
- Performance characterization of the Hyperion Imaging Spectrometer instrumentPublished by SPIE-Intl Soc Optical Eng ,2000
- Unified approach to pre- and in-flight satellite-sensor absolute radiometric calibrationPublished by SPIE-Intl Soc Optical Eng ,1995
- Uncertainties in the in-flight calibration of sensors with reference to measured ground sites in the 0.4-1.1 μm rangeRemote Sensing of Environment, 1994
- Reflectance- and radiance-based methods for the in-flight absolute calibration of multispectral sensorsRemote Sensing of Environment, 1987
- A Numerical Solution to the Equation of Radiative TransferJournal of the Atmospheric Sciences, 1965