Genotyping short tandem repeats using flow injection and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
- 13 February 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (5) , 348-350
- https://doi.org/10.1002/rcm.234
Abstract
Characterizing polymerase chain reaction (PCR) amplicons has been accomplished for the first time using flow injection analysis coupled to electrospray ionization mass spectrometry (ESI-MS). The PCR amplicons were amplified at the human tyrosine hydroxylase short tandem repeat locus from an individual homozygotic for the 9.3 allele. One product was amplified using Pfu polymerase and yielded a blunt-ended amplicon of 82 base-pairs (bp) in length. The second PCR product was amplified using Taq polymerase that resulted in an amplicon with cohesive termini of 82 bp plus either mono- or diadenylation. The two PCR amplicons were alternatively injected using a 0.5-µL loop at 2 µM for the Pfu amplicon and 1 µM for the Taq amplicon with a flow rate of 200 nL/min during data acquisition. Both PCR amplicons were accurately identified using mass measurements illustrating the compatibility of ESI-MS for genotyping short tandem repeat sequences and the potential for high-throughput genotyping of large PCR amplicons. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- Fourier transform ion cyclotron resonance mass spectrometry as a high throughput affinity screen to identify RNA binding ligandsTrAC Trends in Analytical Chemistry, 2000
- External accumulation of ions for enhanced electrospray ionization fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 1997
- Utility of organic bases for improved electrospray mass spectrometry of oligonucleotidesRapid Communications in Mass Spectrometry, 1995
- Rapid Sequencing of Oligonucleotides by High-Resolution Mass SpectrometryJournal of the American Chemical Society, 1994
- Detection of oligonucleotide duplex forms by ion-spray mass spectrometryTetrahedron Letters, 1993
- Preservation of non‐covalent associations in electrospray ionization mass spectrometry: Multiply charged polypeptide and protein dimersJournal of Mass Spectrometry, 1992
- Detection of noncovalent receptor-ligand complexes by mass spectrometryJournal of the American Chemical Society, 1991
- Electrospray Ionization for Mass Spectrometry of Large BiomoleculesScience, 1989
- Interpreting mass spectra of multiply charged ionsAnalytical Chemistry, 1989
- Fourier transform ion cyclotron resonance spectroscopyChemical Physics Letters, 1974