Abstract
An amplifier is described which uses a four electrode tube of the ordinary type, and gives maximum current sensitivities of the order of 10−18 amperes. A novel feature consists in using as grid leak the positive ion emission of the filament.

This publication has 5 references indexed in Scilit: