Statistical methods to correct for verification bias in diagnostic studies are inadequate when there are few false negatives: a simulation study
Open Access
- 11 November 2008
- journal article
- research article
- Published by Springer Nature in BMC Medical Research Methodology
- Vol. 8 (1) , 75
- https://doi.org/10.1186/1471-2288-8-75
Abstract
A common feature of diagnostic research is that results for a diagnostic gold standard are available primarily for patients who are positive for the test under investigation. Data from such studies are subject to what has been termed "verification bias". We evaluated statistical methods for verification bias correction when there are few false negatives. A simulation study was conducted of a screening study subject to verification bias. We compared estimates of the area-under-the-curve (AUC) corrected for verification bias varying both the rate and mechanism of verification. In a single simulated data set, varying false negatives from 0 to 4 led to verification bias corrected AUCs ranging from 0.550 to 0.852. Excess variation associated with low numbers of false negatives was confirmed in simulation studies and by analyses of published studies that incorporated verification bias correction. The 2.5th – 97.5th centile range constituted as much as 60% of the possible range of AUCs for some simulations. Screening programs are designed such that there are few false negatives. Standard statistical methods for verification bias correction are inadequate in this circumstance.This publication has 18 references indexed in Scilit:
- Multiple imputation for correcting verification bias by Ofer Harel and Xiao‐Hua Zhou, Statistics in Medicine 2006; 25:3769–3786Statistics in Medicine, 2007
- [18F]Fluorodeoxyglucose Uptake by Positron Emission Tomography for Diagnosis of Suspected Lung CancerArchives of internal medicine (1960), 2007
- Systematic reviews of diagnostic tests in cancer: review of methods and reportingBMJ, 2006
- Assessing Prostate Cancer Risk: Results from the Prostate Cancer Prevention TrialJNCI Journal of the National Cancer Institute, 2006
- Assessing Accuracy of a Continuous Screening Test in the Presence of Verification BiasJournal of the Royal Statistical Society Series C: Applied Statistics, 2004
- Effect of Verification Bias on Screening for Prostate Cancer by Measurement of Prostate-Specific AntigenNew England Journal of Medicine, 2003
- Results of a prospective multicenter study for evaluation of the diagnostic quality of an open whole-body low-field MRI unit.European Journal of Radiology, 1999
- Sex and Test Verification BiasCirculation, 1997
- Testing for Fetal Pulmonary MaturityMedical Decision Making, 1990
- Construction of Receiver Operating Characteristic Curves when Disease Verification Is Subject to Selection BiasMedical Decision Making, 1984