A comparative multicentre trial of spinal needles for Caesarean section
Open Access
- 1 October 1997
- journal article
- clinical trial
- Published by Wiley in Anaesthesia
- Vol. 52 (10) , 1005-1011
- https://doi.org/10.1111/j.1365-2044.1997.191-az0324.x
Abstract
We studied 681 patients in a randomised, multicentre, double‐blind, parallel group trial designed to assess the incidence of headache following spinal anaesthesia for Caesarean section using four different pencil point spinal needles. The needles used were: Whitacre 25G (n = 170), Polymedic 25G (n = 170), Sprotte 24G (n = 173) and Polymedic 24G (n = 168). The incidence of all headaches prior to discharge was 11.1%. Only five headaches (0.75%) were severe with features of post dural puncture headache (PDPH) and required an epidural blood patch: Whitacre 25G = 0, Polymedic 25G = 1 (0.6%), Sprotte 24G = 2 (1.2%), Polymedic 24G = 2 (1.2%). There was no statistically significant difference between the four groups for PDPH. We conclude that all four needles studied performed satisfactorily and comparably.Keywords