An NO2 calibration system, based upon a permeation device and a two‐stage dynamic dilution system, was designed, constructed, and characterized at the National Bureau of Standards. In this system, calibrant flow entering the second stage was controlled without contacting a metal flow controller, and permeation oven temperature and flow were continuously maintained, even during transport. The system performance and the permeation emission rate were characterized by extensive laboratory tests based on gravimetry, chemiluminescence detection, and tunable diode laser absorption spectroscopy. This system was capable of accurately delivering known NO2 concentrations in the ppbv and sub‐ppbv concentration range with a total uncertainty of approximately 10%. Upon completion of these tests the calibration system was placed on board NASA's research aircraft at both the Wallops Island and Ames research facilities. There it was employed as the reference standard in NASA's Global Tropospheric Experiment/Chemical Instrumentation Test and Evaluation 2 mission in August 1986, as discussed in a companion paper (Gregory et al., this issue).This publication has 11 references indexed in Scilit:
- Determination of nitrogen dioxide in air-compressed gas mixtures by quantitative tunable diode laser absorption spectrometry and chemiluminescence detectionAnalytical Chemistry, 1988
- Determination of sulfur dioxide by pulsed ultraviolet laser photoacoustic spectroscopyAnalytical Chemistry, 1987
- Intercomparison of two techniques for the preparation of gaseous sulfur calibration standards in the low to sub-ppb rangeAtmospheric Environment (1967), 1987
- A dynamic dilution system for the production of sub-ppb concentrations of reactive and labile speciesAtmospheric Environment (1967), 1986
- Evaluation of a catalytic reduction technique for the measurement of total reactive odd-nitrogen NO y in the atmosphereJournal of Atmospheric Chemistry, 1985
- Further modification of a commercial NOx detector for high sensitivityReview of Scientific Instruments, 1984
- Laser photoacoustic detection of nitrogen dioxide in the gas-phase titration of nitric oxide with ozoneAnalytical Chemistry, 1982
- Performance of a nitrogen dioxide permeation deviceAnalytical Chemistry, 1977
- Preparation of known concentrations of gases and vapors with permeation devices calibrated gravimetricallyAnalytical Chemistry, 1970
- Primary Standards for Trace Gas Analysis.Analytical Chemistry, 1966