Normal range for transdiaphragmatic pressures during sniffs with catheter mounted transducers.
Open Access
- 1 July 1993
- Vol. 48 (7) , 750-753
- https://doi.org/10.1136/thx.48.7.750
Abstract
BACKGROUND--Transdiaphragmatic pressure (sniff PDI) during maximal sniffs is a useful clinical test of inspiratory muscle function. Although a normal range has been established for sniff PDI using air filled balloons, no comparable data are available for catheter mounted pressure transducers. METHODS--Using a single catheter with two pressure transducers 15 cm apart, oesophageal and gastric pressures were recorded in 50 normal volunteers (25 women), five of each sex from each decade between the third and seventh decades of life. Each subject performed 10 maximal sniffs at functional residual capacity. RESULTS--Mean (SD) sniff PDI was 149 (32) cm H2O in men and 127 (22) cm H2O in women. The lower limits of normal for sniff PDI (mean -1.96 x SD) after logarithmic transformation of the data were 95 and 78 cm H2O in men and women respectively. CONCLUSIONS--With this technique transdiaphragmatic pressure can be measured using a single catheter which can easily be cleaned and reused. The values for sniff PDI are similar to those recorded previously with air filled balloons, suggesting that the method of recording pressure does not significantly affect the values obtained.Keywords
This publication has 16 references indexed in Scilit:
- Predicted normal values for maximal respiratory pressures in caucasian adults and children.Thorax, 1984
- Respiratory Pressures and Function in Young Adults1–4American Review of Respiratory Disease, 1983
- Assessment of the catheter tip pressure transducer for use in infant lung function testsMedical & Biological Engineering & Computing, 1982
- Limitations of measurement of transdiaphragmatic pressure in detecting diaphragmatic weakness.Thorax, 1981
- Inspiratory muscle force in normal subjects and patients with interstitial lung disease.Thorax, 1980
- Measurement of transdiaphragmatic pressure with a single gastric-esophageal probeJournal of Applied Physiology, 1979
- A technique for measuring frequency response of pressure, volume, and flow transducersJournal of Applied Physiology, 1979
- Dynamic characteristics of air-filled differential pressure transducersJournal of Applied Physiology, 1979
- Maximal respiratory pressures: normal values and relationship to age and sex.Published by Elsevier ,1969
- Improved technique for estimating pleural pressure from esophageal balloonsJournal of Applied Physiology, 1964