Polypropylene small‐diameter vascular grafts
- 1 October 1992
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 26 (10) , 1383-1394
- https://doi.org/10.1002/jbm.820261009
Abstract
Polypropylene's physical properties (e.g., high tensile strength) and relatively inert behavior suggest that fabrication into an arterial substitute may result in an efficacious prosthesis. Grafts were woven from polypropylene yarn into conduits 4 mm I.D. × 50 mm in length. Control grafts were Dacron and ePTFE. Baseline platelet aggregometry on all dogs was performed with 10−5M ADP. Aspirin and dipyridamole were given for three days preoperatively and maintained for 2 weeks after surgery. Fifty‐four grafts were placed into the aortoiliac position, two different graft materials per dog. The grafts were explanted at intervals of 2 weeks through 16 months; photographed for thrombusfree surface area determinations; and preserved for light, scanning, and transmission electron microscopy. Late (4–16 month) patency was 81% (13/16) for polypropylene, 69% (9/13) for Dacron, and 20% (1/5) for ePTFE. These data include one year patencies of 11/12 (92%) for polypropylene and 7/10 (70%) for Dacron. Late patency for polypropylene grafts was better than for PTFE (p < 0.05). Platelet aggregation status did not predict graft patency. Light microscopy of 2‐week polypropylene explants showed inner capsules composed of myofibroblasts and macrophages, with patchy areas of endothelial cells lining the lumen. By 1 month, a confluent endothelialized surface was seen in all polypropylene explants. Progressive thickening of inner capsules with myofibroblasts and collagen continued through 4 months, reaching a mean thickness of 142 ± 50 μm compared to 150 ± 30 μm for Dacron. These findings suggest potential clinical efficacy for polypropylene as an arterial substitute. © 1992 John Wiley & Sons, Inc.Keywords
This publication has 9 references indexed in Scilit:
- Surgical Manipulation and the Tensile Strength of Polypropylene SuturesArchives of Surgery, 1989
- Polyglactin 910/polydioxanone bicomponent totally resorbable vascular prosthesesJournal of Vascular Surgery, 1988
- Polypropylene suture stresses after closure of longitudinal arteriotomyJournal of Vascular Surgery, 1988
- Arterial Regeneration Over Polydioxanone Prostheses in the RabbitArchives of Surgery, 1987
- Compound polyglactin 910/polypropylene small vessel prosthesesJournal of Vascular Surgery, 1987
- Dacron inhibition of arterial regenerative activitiesJournal of Vascular Surgery, 1986
- Arterial Regeneration Over Absorbable ProsthesesArchives of Surgery, 1982
- Mechanical Properties of Prolene® and Ethilon® Sutures After Three Weeks in VivoScandinavian Journal of Plastic and Reconstructive Surgery, 1982
- Thrombogenicity of different suture materials as revealed by scanning electron microscopyJournal of Biomedical Materials Research, 1980