Mixture Analysis Using a Quadrupole Mass Filter/Quadrupole Ion Trap Mass Spectrometer
- 1 January 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (4) , 659-667
- https://doi.org/10.1021/ac950978s
Abstract
A hybrid tandem mass spectrometer is constructed by interfacing a quadrupole mass filter (Q) to a quadrupole ion trap mass spectrometer (QITMS) and is evaluated for the analysis of mixtures. The mass filter is set to selectively inject ions of a particular m/z or, in scanning mode, to sequentially inject ions into the QITMS for subsequent manipulation and detection. Performance of the instrument is demonstrated using a mixture of ions created by electron impact ionization of perfluorotributylamine (FC-43) and peptide ions generated by pulsed Cs+ bombardment. Resulting data are compared to those obtained by utilizing only the ion trap. Molecular weight, fragmentation, and high-resolution analyses for the sequentially injected mass-filtered peptides show improved performance over similar measurements employing only the ion trap mass spectrometer. Performance is optimized when ions are not rf-isolated in the QITMS. Using the hybrid, a resolution of 33 200 is achieved for angiotensin I. Dramatic reduction of space charge-induced signal suppression is demonstrated for LSIMS of Glu-fibrinopeptide B. “On-the-fly” collision-induced dissociation is performed for m/z 502 from FC-43, where fragmentation is induced by increasing the ion injection energy. Collision-induced dissociation efficiencies for fragmentation of angiotensin I by resonance excitation are investigated as a function of cooling time for different modes of operation of the hybrid. A current limitation of the instrument is the time required to port the data for acquisition.Keywords
This publication has 27 references indexed in Scilit:
- A novel quadrupole, quistor, quadrupole tandem mass spectrometerJournal of Mass Spectrometry, 1991
- A sector/ion trap hybrid mass spectrometer of BE/trap configurationInternational Journal of Mass Spectrometry and Ion Processes, 1990
- Ion isolation and sequential stages of mass spectrometry in a quadrupole ion trap mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1990
- Consecutive reaction monitoring in a four-sector mass spectrometer: MS4 and one step beyondAnalytical Chemistry, 1988
- Collisionally activated decomposition of leucine-enkephalin and analogues using a hybrid tandem mass spectrometerRapid Communications in Mass Spectrometry, 1988
- A tandem time-of-flight mass spectrometer for surface-induced dissociationInternational Journal of Mass Spectrometry and Ion Processes, 1987
- Selective analysis of metastable ionsMass Spectrometry Reviews, 1985
- A hybrid BEQQ mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1985
- A new “hybrid” sector/quadrupole mass spectrometer for mass spectrometry/mass spectrometryInternational Journal of Mass Spectrometry and Ion Physics, 1982
- Collision-induced decompositions of aromatic molecular ionsInternational Journal of Mass Spectrometry and Ion Physics, 1968