High Performance Liquid Chromatographic Assay for Basic Amine Drugs in Plasma and Urine Using a Silica Gel Column and an Aqueous Mobile Phase. II. Chlorpheniramine
- 1 October 1987
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 10 (14) , 3101-3112
- https://doi.org/10.1080/01483918708068300
Abstract
A high performance liquid chromatographic [HPLC] method that involves the use of a silica gel column and an aqueous mobile phase for quantitation of chlorpheniramine in plasma and urine is presented. Alkalinized samples are cleaned by extraction with pentane [containing 1% CH3CN], and the extraction is followed by evaporating the solvent and reconstituting the residue in a small amount of mobile phase. An aliquot of this solution is analyzed by an HPLC system with an Ultrasphere Si Column, an aqueous mobile phase at pH 7 containing 60% CH3CN and 7.5 mM [NH4]2HPO4, and UV detection at 200 nm. Although the average recovery of extraction is 58% ± SD 10%, the detection limit for the method is 0.7 ng/ml in plasma and 100 ng/ml in urine [s/n = 3] for 0.5 ml samples. The coefficients of variation [CV] on the results of samples run to measure interday and intraday precision and the bias on control samples were all 10% or less. We have used the method in a bioavailability study of a controlled release formulation involving over 1000 samples.This publication has 10 references indexed in Scilit:
- High Performance Liquid Chromatographic Assay of Methoclopramide in Plasma Using a Silica Gel Column and An Aqueous Meobile PhaseAnalytical Letters, 1987
- High-performance liquid chromatographic assay of basic amine drugs in plasma and urine using a silica gel column and an aqueous mobile phase : I. AmilorideJournal of Chromatography B: Biomedical Sciences and Applications, 1986
- Subnanogram Quantitation of Chlorpheniramine in Plasma by a New Radioimmunoassay and Comparison With a Liquid Chromatographic MethodJournal of Pharmaceutical Sciences, 1984
- Separation of organic amine compounds on silica gel with reversed-phase eluentsAnalytical Chemistry, 1982
- Sensitive GLC–mass spectrometric determination of chlorpheniramine in serumJournal of Pharmaceutical Sciences, 1980
- Improvements in liquid chromatography column life and method flexibility by saturating the mobile phase with silicaJournal of Chromatography A, 1979
- ChlorpheniramineJournal of Chromatography B: Biomedical Sciences and Applications, 1979
- Simplified gas chromatographic method for the determination of chlorpheniramine in serumAnalytical Chemistry, 1977
- Mass fragmentographic determination of d- and l-chlorpheniramine with aid of the stable isotope technique.CHEMICAL & PHARMACEUTICAL BULLETIN, 1976