Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations
- 10 November 1999
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 44 (12) , 2879-2895
- https://doi.org/10.1088/0031-9155/44/12/302
Abstract
The correction of scattered radiation is one of the most challenging tasks in 3D positron emission tomography (PET) and knowledge about the amount of scatter and its distribution is a prerequisite for performing an accurate correction. One concern in 3D PET in contrast to 2D PET is the scatter contribution from activity outside the field-of-view (FOV) and multiple scatter. Using Monte Carlo simulations, we examined the scatter distribution for various phantoms. The simulations were performed for a whole-body PET system (ECAT EXACT HR+, Siemens/CTI) with an axial FOV of 15.5 cm and a ring diameter of 82.7 cm. With (without) interplane septa, up to one (two) out of three detected events are scattered (for a centred point source in a water-filled cylinder that nearly fills out the patient port), whereby the relative scatter fraction varies significantly with the axial position. Our results show that for an accurate scatter correction, activity as well as scattering media outside the FOV have to be taken into account. Furthermore it could be shown that there is a considerable amount of multiple scatter which has a different spatial distribution from single scatter. This means that multiple scatter cannot be corrected by simply rescaling the single scatter component.Keywords
This publication has 17 references indexed in Scilit:
- Experimentelle Bestimmung der unteren Energieschwelle eines Positronen-Emissions-TomographenNuklearmedizin-Nuclear Medicine, 1999
- Performance evaluation of the whole-body PET scanner ECAT EXACT HR/sup +/ following the IEC standardIEEE Transactions on Nuclear Science, 1997
- Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECTPhysics in Medicine & Biology, 1996
- Model-based scatter correction for fully 3D PETPhysics in Medicine & Biology, 1996
- Effects of scatter on model parameter estimates in 3D PET studies of the human brainIEEE Transactions on Nuclear Science, 1995
- A Monte Carlo correction for the effect of Compton scattering in 3-D PET brain imagingIEEE Transactions on Nuclear Science, 1995
- Scatter correction in 3-D PETIEEE Transactions on Medical Imaging, 1994
- Scatter correction in the transaxial slices of a whole-body positron emission tomographPhysics in Medicine & Biology, 1993
- Object shape dependent scatter simulations for PETIEEE Transactions on Nuclear Science, 1991
- A Monte Carlo Simulation of Compton Scattering in Positron Emission TomographyJournal of Computer Assisted Tomography, 1983