Synthetic Dialysis Shunts: Thrombolysis with the Cragg Thrombolytic Brush Catheter
- 1 October 1999
- journal article
- clinical trial
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 213 (1) , 180-184
- https://doi.org/10.1148/radiology.213.1.r99oc02180
Abstract
To evaluate the effectiveness of the Cragg thrombolytic brush catheter for declotting of synthetic arteriovenous dialysis shunts. In this randomized controlled trial, 77 patients with synthetic forearm loop shunts that were thrombosed were randomly assigned to undergo pharmacomechanical thrombolysis with a pulsed spray (n = 34) or a thrombolytic brush catheter (n = 43). The following findings were evaluated: declotting time, urokinase dose, procedure time, complications, and shunt patency at the first dialysis session and at 3 months. All data were collected prospectively in an unblinded manner. The total amount of urokinase used, including secondary interventions, was 243,657 IU with the catheter versus 476,563 IU with the pulsed spray (P = .001). At 15 minutes, clot lysis was successful in 66% of the patients with the catheter versus in 19% with the pulsed spray (P = .001). At 30 minutes, clot lysis was successful in 98% with the catheter versus 47% with the pulsed spray (P = .001). Procedure complication rates and patency at 3 months were similar for the catheter and the pulsed-spray groups. Use of the Cragg catheter with urokinase offered faster and more complete clot lysis than did use of the pulsed spray with urokinase. The amount of urokinase used with the catheter was half that used with the pulsed spray. Shunt patency at 3 months was similar for the two treatment methods.Keywords
This publication has 9 references indexed in Scilit:
- Treatment of thrombosed hemodialysis access grafts: Arrow-Trerotola percutaneous thrombolytic device versus pulse-spray thrombolysis. Arrow-Trerotola Percutaneous Thrombolytic Device Clinical Trial.Radiology, 1998
- Current Status of Percutaneous Mechanical Thrombectomy. Part II. Devices and Mechanisms of ActionJournal of Vascular and Interventional Radiology, 1998
- Current Status of Percutaneous Mechanical Thrombectomy. Part I. General PrinciplesJournal of Vascular and Interventional Radiology, 1997
- Percutaneous Intervention for Permanent Hemodialysis Access: A ReviewJournal of Vascular and Interventional Radiology, 1997
- Mechanical thrombolysis for the treatment of thrombosed hemodialysis access grafts.Radiology, 1996
- Pulmonary emboli from pulse-spray and mechanical thrombolysis: evaluation with an animal dialysis-graft model.Radiology, 1996
- Pulse-spray pharmacomechanical thrombolysis of thrombosed hemodialysis access grafts: long-term experience and comparison of original and current techniques.American Journal of Roentgenology, 1995
- Mechanical versus pharmacomechanical thrombolysis for the treatment of thrombosed dialysis access graftsKidney International, 1994
- Pulse-spray pharmacomechanical thrombolysis for treatment of thrombosed dialysis access graftsThe American Journal of Surgery, 1993