Analysis of Nontransparent Polymers: Mixture Design, Second-Derivative Attenuated Total Internal Reflectance FT-IR, and Multivariate Calibration
- 1 June 1992
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 46 (6) , 1002-1008
- https://doi.org/10.1366/0003702924124457
Abstract
The composition of nontransparent polymers has been predicted from the fingerprint region in the mid-IR. The polymers were analyzed by the Horizontal Attenuated Total internal Reflection (HATR) FT-IR technique. The polymers were blends of three different master batches: (1) a polymer of ethylene with carbon black, (2) a co-polymer of ethylene and propylene monomers, and (3) an ethylene-propylene-diene elastomer. A calibration set was defined by use of mixture design. Partial least-squares (PIS) regression was used to calculate models for prediction of the relative concentrations of each master batch (one at a time). Second-derivated IR profiles normalized to 100% were used as predictive variables. Two alternative criteria were compared for optimizing the predictive ability of the calibration models: (1) squared prediction error of all the calibration samples, and (2) prediction error of replicated calibration samples of the centerpoint in the design only. The latter criterion turned out to be the more useful for the purpose of this study. This is because the centerpoint represents the target sample of the blending process. The one-component PLS models, suggested by the latter optimization criterion, gave predictions within 1% of the stated relative concentrations and with standard deviations from 0.5 to 1.3% for all three master batches.Keywords
This publication has 17 references indexed in Scilit:
- Multivariate prediction and background correction using local modeling and derivative spectroscopyAnalytical Chemistry, 1991
- Multivariate analysis of carbon-13 nuclear magnetic resonance spectra. Identification and quantification of average structures in petroleum distillatesAnalytical Chemistry, 1990
- Interpretation of latent-variable regression modelsChemometrics and Intelligent Laboratory Systems, 1989
- Analysis of EPDM Terpolymers by Near-Infrared Spectroscopy and Multivariate Calibration MethodsApplied Spectroscopy, 1989
- Prediction of physical properties of hydrocarbon mixtures by partial-least-squares calibration of carbon-13 nuclear magnetic resonance dataAnalytica Chimica Acta, 1989
- PLS regression methodsJournal of Chemometrics, 1988
- Multivariate calibration of diffuse reflectance infrared spectra of coals as an alternative to rank determination by vitrinite reflectanceChemometrics and Intelligent Laboratory Systems, 1987
- Light sensor for ultrahigh vacuum systems utilizing a silicon photovoltaic cellApplied Optics, 1976
- Smoothing and Differentiation of Data by Simplified Least Squares Procedures.Analytical Chemistry, 1964
- Attenuated total reflectionSpectrochimica Acta, 1961