How does the degree of carotid stenosis affect the accuracy and interobserver variability of magnetic resonance angiography?
Open Access
- 1 August 2001
- journal article
- research article
- Published by BMJ in Journal of Neurology, Neurosurgery & Psychiatry
- Vol. 71 (2) , 155-160
- https://doi.org/10.1136/jnnp.71.2.155
Abstract
The accuracy of magnetic resonance angiography (MRA) was determined in patients with recently symptomatic tight (80%-99%) carotid stenosis (on Doppler ultrasound), and the effect of stenosis severity on the accuracy and interobserver variability of MRA was studied. Forty four consecutive patients undergoing intra-arterial angiography (IAA) before carotid endarterectomy were prospectively studied, in two centres with identical MR scanners and sequences. All patients had undergone Doppler ultrasound, showing a 70% or worse carotid stenosis on the symptomatic side. MRA and IAA were done during the same admission. The MRA films were each independently and blindly read for percentage stenosis (signal gap if present) by four observers. The IA angiograms were read separately by one observer, blind to symptoms, and Doppler and MRA results. Signal gaps on MRA were seen in stenoses ranging from 67% to 99% on intra-arterial angiography. Magnetic resonance angiograms consistently overestimated the percentage stenosis according to intra-arterial angiography. Clinically significant misclassification of stenosis occurred according to MRA in 7% of patients, and was more frequent as carotid stenosis increased. Significant diagnostic errors occur with MRA in patients with tight carotid stenosis. Any morbidity occurring as a result of misclassification by MRA is likely to be offset by the avoidance of complications; however, this could only be determined with certainty in a randomised controlled trial.Keywords
This publication has 11 references indexed in Scilit:
- Intracranial vascular stenosis and occlusion: MR angiographic findings.1997
- Specificity of MR angiography as a confirmatory test of carotid artery stenosis.1996
- Clinical significance of the flow gap in carotid magnetic resonance angiographyJournal of Neurosurgery, 1996
- Observer variation in the interpretation of intra-arterial angiograms and the risk of inappropriate decisions about carotid endarterectomy.Journal of Neurology, Neurosurgery & Psychiatry, 1996
- Noninvasive Carotid Artery Testing: A Meta-analytic ReviewAnnals of Internal Medicine, 1995
- Prognostic value and reproducibility of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. European Carotid Surgery Trialists' Collaborative Group.Stroke, 1994
- Comparison of magnetic resonance angiography, duplex ultrasound, and digital subtraction angiography in assessment of extracranial internal carotid artery stenosis.Journal of Neurology, Neurosurgery & Psychiatry, 1994
- Measurement of internal carotid artery stenosis from source MR angiograms.Radiology, 1994
- Cerebral angiographic risk in mild cerebrovascular disease.Stroke, 1990
- Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic TestsNew England Journal of Medicine, 1978