Nanosecond x-ray pictures recorded with a pulsed channel plate
- 1 January 1976
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 47 (1) , 88-89
- https://doi.org/10.1063/1.1134499
Abstract
A channel plate phosphor system has been electrically pulsed in order to obtain time and space resolved images of a fast varying x‐ray source. Effective exposure times of about 3 nsec have been realized. Plasma focus x‐ray pictures obtained by this method are presented.Keywords
This publication has 4 references indexed in Scilit:
- The use of a microchannel electron multiplier in spectroscopic instrumentation, involving frequent vacuum breakingReview of Scientific Instruments, 1974
- Preliminary results with saturable microchannel array platesReview of Scientific Instruments, 1974
- AdvertisementJournal of Chemical Documentation, 1972
- A High Resolution, High Sensitivity Channel Plate Image Intensifier for Use in Particle SpectrographsReview of Scientific Instruments, 1971