A Broad Diagnostic Battery for Bedside Transcranial Doppler to Detect Flow Changes With Internal Carotid Artery Stenosis or Occlusion
- 1 July 2001
- journal article
- Published by Wiley in Journal of Neuroimaging
- Vol. 11 (3) , 236-242
- https://doi.org/10.1111/j.1552-6569.2001.tb00040.x
Abstract
Background and Purpose. The authors establish accuracy parameters of a broad diagnostic battery for bedside transcranial Doppler (TCD) to detect flow changes due to internal carotid artery (ICA) stenosis or occlusion. Methods. The authors prospectively studied consecutive patients with stroke or transient ischemic attack referred for TCD. TCD was performed and interpreted at bedside using a standard insonation protocol. A broad diagnostic battery included major criteria: collateral flow signals, abnormal siphon or terminal carotid signals, and delayed systolic flow acceleration in the middle cerebral artery. Minor criteria included a unilateral decrease in pulsatility index (≤ 0.6 or ≤ 70% of contralateral side), flow diversion signs, and compensatory velocity increase. Angiography or carotid duplex ultrasound (CDU) was used to grade the degree of carotid stenosis using North American criteria. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of TCD findings were determined. Results. Seven hundred and twenty patients underwent TCD, of whom 517 (256 men and 261 women) had angiography and/or CDU within 8.8 ± 0.9 days. Age was 63.1 ± 15.7 years. For a 70% to 99% carotid stenosis or occlusion, TCD had sensitivity of 79.4%, specificity of 86.2%, PPV of 57.0%, NPV of 94.8%, and accuracy of 84.7%. For a 50% to 99% carotid stenosis or occlusion, TCD had sensitivity of 67.5%, specificity of 83.9%, PPV of 54.5%, NPV of 90.0%, and accuracy of 81.6%. TCD detected intracranial carotid lesions with 84.9% accuracy and extracranial carotid lesions with 84.4% accuracy (sensitivity of 88% and 79%, specificity of 85% and 86%, PPV of 24% and 54%, and NPV of 99% and 95%, respectively). The prevalence of the ophthalmic artery flow reversal was 36.4% in patients with ≥ 70% stenosis or occlusion. If present, this finding indicated a proximal ICA lesion location in 97% of these patients. Conclusions. In symptomatic patients, bedside TCD can accurately detect flow changes consistent with hemodynamically significant ICA obstruction; however, TCD should not be a substitute for direct carotid evaluation. Because TCD is sensitive and specific for ≥ 70% carotid stenosis or occlusion in both extracranial and intracranial carotid segments, it can be used as a complementary test to refine other imaging findings and detect tandem lesions.Keywords
This publication has 15 references indexed in Scilit:
- Grading Carotid Stenosis With UltrasoundStroke, 1997
- Transcranial Doppler Ultrasound Battery Reliably Identifies Severe Internal Carotid Artery StenosisStroke, 1997
- Clinical significance of the flow gap in carotid magnetic resonance angiographyJournal of Neurosurgery, 1996
- How should we estimate carotid stenosis using magnetic resonance angiography?Neuroradiology, 1996
- Accuracy of initial stroke subtype diagnosis in the TOAST studyNeurology, 1995
- Detection and quantification of carotid artery stenosis: efficacy of various Doppler velocity parameters.American Journal of Roentgenology, 1993
- Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid StenosisNew England Journal of Medicine, 1991
- Noninvasive detection of occlusive disease of the carotid siphon and middle cerebral arteryAnnals of Neurology, 1990
- Quantitation of carotid stenosis with continuous-wave (C-W) Doppler ultrasound.Stroke, 1979