A comparison of simultaneous measurements of systolic function in the baboon by electromagnetic flowmeter and high frame rate ECG-gated blood pool scintigraphy.
- 1 August 1979
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 60 (2) , 312-319
- https://doi.org/10.1161/01.cir.60.2.312
Abstract
Left ventricular (LV) systolic timing and relative volume variations were simultaneously measured by electromagnetic flowmeter (EMF) and high frame rate ECG-gated blood pool scintigraphy in five baboons. No significant differences (p greater than 0.1, paired t test) were observed in the time (from R wave) to peak aortic flow (maximum LV ejection rate), time to cessation of aortic flow (end-systole) or in the duration of aortic flow (LV ejection time). A small (approximately 15 msec) but significant systematic difference (p less than 0.02) was noted in the time to onset of aortic flow. The shape of each scintigraphic time-activity curve during systole was compared to an equivalent curve synthesized from 10 EMF flow profiles obtained in the same baboon. Comparison of these paired curves over systolic ejection yielded an average correlation or r = 0.95 (range 0.90--0.99). The ratio of peak flow to stroke volume determined from these data did not differ significantly (p greater than 0.05). In the baboon, quantitative high temporal resolution ECG-gated scintigraphy appears to reflect closely the detailed timing and relative magnitude variation of LV volume during the entire period of systolic ejection. We conclude that the assumptions underlying the scintigraphic method are valid in the baboon during the ejection interval.This publication has 11 references indexed in Scilit:
- EVALUATION OF LEFT-VENTRICULAR FUNCTION IN NORMAL PERSONS AND PATIENTS WITH HEART-DISEASE1978
- Analysis of left ventricular function from multiple gated acquisition cardiac blood pool imaging. Comparison to contrast angiography.Circulation, 1977
- REAL-TIME SYSTEM FOR MULTI-IMAGE GATED CARDIAC STUDIES1977
- RADIONUCLIDE LEFT VENTRICULOGRAPHY WITH SLANT HOLE COLLIMATOR1977
- ECG-GATED SCINTILLATION PROBE MEASUREMENT OF LEFT-VENTRICULAR FUNCTION1977
- RADIONUCLIDE EJECTION FRACTION - COMPARISON OF 3 RADIONUCLIDE TECHNIQUES WITH CONTRAST ANGIOGRAPHY1977
- The nuclear stethoscope: A simple device for generation of left ventricular volume curvesThe American Journal of Cardiology, 1976
- A computer processing system for ECG-gated radioisotope angiography of the human heartComputers and Biomedical Research, 1976
- Left ventricular internal diameter and cardiac function in conscious dogs.Journal of Applied Physiology, 1969
- The influence of atrial contraction and mitral valve mechanics on ventricular fillingAmerican Heart Journal, 1969