On the detector arrangement for in-beam PET for hadron therapy monitoring
- 10 April 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (9) , 2143-2163
- https://doi.org/10.1088/0031-9155/51/9/002
Abstract
In-beam positron emission tomography (in-beam PET) is currently the only method for an in situ monitoring of highly tumour-conformed charged hadron therapy. At the experimental carbon ion tumour therapy facility, running at the Gesellschaft für Schwerionenforschung, Darmstadt, Germany, all treatments have been monitored by means of a specially adapted dual-head PET scanner. The positive clinical impact of this project triggered the construction of a hospital-based hadron therapy facility, with in-beam PET expected to monitor more delicate radiotherapeutic situations. Therefore, we have studied possible in-beam PET improvements by optimizing the arrangement of the gamma-ray detectors. For this, a fully 3D, rebinning-free, maximum likelihood expectation maximization algorithm applicable to several closed-ring or dual-head tomographs has been developed. The analysis of beta(+)-activity distributions simulated from real-treatment situations and detected with several detector arrangements allows us to conclude that a dual-head tomograph with narrow gaps yields in-beam PET images with sufficient quality for monitoring head and neck treatments. For monitoring larger irradiation fields, e.g. treatments in the pelvis region, a closed-ring tomograph was seen to be highly desirable. Finally, a study of the space availability for patient and bed, tomograph and beam portal proves the implementation of a closed-ring detector arrangement for in-beam PET to be feasible.Keywords
This publication has 15 references indexed in Scilit:
- Dose quantification from in-beam positron emission tomographyRadiotherapy and Oncology, 2004
- Fast neutrons produced by nuclear fragmentation in treatment irradiations with 12C beamRadiation Protection Dosimetry, 2004
- Charged hadron tumour therapy monitoring by means of PETNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Evaluation of therapeutic potential of heavy ion therapy for patients with locally advanced prostate cancerInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Influence of setup errors on spinal cord dose and treatment plan quality for cervical spine tumours: a phantom study for photon IMRT and heavy charged particle radiotherapyPhysics in Medicine & Biology, 2003
- Attenuation and scatter correction for in-beam positron emission tomography monitoring of tumour irradiations with heavy ionsPhysics in Medicine & Biology, 2003
- Treatment planning for heavy ion radiotherapy: clinical implementation and applicationPhysics in Medicine & Biology, 2001
- The investigation of different cameras for in-beam PET imagingPhysics in Medicine & Biology, 1996
- Magnetic scanning system for heavy ion therapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993
- A Multicrystal Two Dimensional BGO Detector System for Positron Emission TomographyIEEE Transactions on Nuclear Science, 1986