Rapid radioimmunoassay for serum myoglobin
- 1 October 1980
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 239 (4) , H565
- https://doi.org/10.1152/ajpheart.1980.239.4.h565
Abstract
A rapid radioimmunoassay for serum myoglobin concentration has been developed, capitalizing on a technique for rapid separation of antibody-bound antigen from free antigen using Sepharose-bound sheep anti-rabbit γ-globulin. Total time required for the assay is 2.75 h, making it suitable for clinical approaches employing myoglobin for rapid identification of patients in the active phase of myocardial injury.This publication has 2 references indexed in Scilit:
- Radioimmunoassay for human myoglobin. Initial experience in patients with coronary heart disease.Circulation, 1978
- Myoglobinemia as Index to Myocardial InfarctionAnnals of Internal Medicine, 1977