Comparing PEROXONE and Ozone for Controlling Taste and Odor Compounds, Disinfection By‐products, and Microorganisms
- 1 April 1990
- journal article
- research article
- Published by Wiley in Journal AWWA
- Vol. 82 (4) , 181-191
- https://doi.org/10.1002/j.1551-8833.1990.tb06950.x
Abstract
The Metropolitan Water District of Southern California is evaluating the hydrogen peroxide‐ozone (PEROXONE) advanced oxidation process (followed by secondary disinfection with chloramines) for removal of taste and odor compounds, control of disinfection byproducts (DBPs), and inactivation of microorganisms. This article reports the results of pilot‐scale testing designed to optimize the H2O2:O3 ratio and to compare ozone and PEROXONE at different contact times. The tests described represent one phase of a five‐phase PEROXONE pilot‐scale study for treating water from the California State Water Project and from the Colorado River. Results to date indicate that the PEROXONE process requires a significantly lower applied ozone dosage to oxidize 2‐methylisobomeol and geosmin as compared with ozone alone. The levels of DBPs formed when ozone or PEROXONE is used (followed by chloramines) are low, and PEROXONE (at H2O2:O3 ratios of ≤0.3) is comparable with ozone for the inactivation of microorganisms.Keywords
This publication has 12 references indexed in Scilit:
- Inactivation of Giardia muris and indicator organisms seeded in surface water supplies by PEROXONE and ozoneEnvironmental Science & Technology, 1989
- The Determination of Carbonyl Compounds in Ozonated Water by the PFBOA MethodOzone: Science & Engineering, 1989
- Advanced Oxidation Processes for Treating Groundwater Contaminated With TCE and PCE: Pilot‐Scale EvaluationsJournal AWWA, 1988
- Interactions Between Ozone, Halogens and Organic CompoundsOzone: Science & Engineering, 1988
- The Chemistry of Water Treatment Processes Involving Ozone, Hydrogen Peroxide and Ultraviolet RadiationOzone: Science & Engineering, 1987
- Derivatization technique for the determination of peroxides in precipitationAnalytical Chemistry, 1986
- Determination of subnanogram-per-liter levels of earthy-musty odorants in water by the salted closed-loop stripping methodEnvironmental Science & Technology, 1984
- Factors promoting in vitro excystation of Giardia muris cystsTransactions of the Royal Society of Tropical Medicine and Hygiene, 1984
- Determination of Ozone In Water By The Indigo Method: A Submitted Standard MethodOzone: Science & Engineering, 1982
- BacteriophagesPublished by Biodiversity Heritage Library ,1959