Non-invasive detection of gastro-oesophageal reflux using an ambulatory system.
Open Access
- 1 November 1993
- Vol. 34 (11) , 1482-1486
- https://doi.org/10.1136/gut.34.11.1482
Abstract
The aim of this study was the separate measurement of reflux of food and acid into the oesophagus in 37 healthy, ambulant subjects. This was performed by radiolabelling the food and monitoring its reflux with a small directional gamma detector, which was placed externally over the oesophagus, and connected to an ambulatory data recorder. The pH was measured with a conventional oesophageal pH electrode. This method permitted the separate characterisation of acid and neutral (food) components of gastro-oesophageal reflux. The gastric emptying characteristics of the test meal were also monitored by gamma scintigraphy in a separate experiment. The oesophageal pH fell below 4 for 3.2 + 8.6/-2.3% (mean (SD)) of the recording time. Food reflux alone occurred for 17.8 + 53.2/-13.8% of the recording time. Simultaneous food and acid reflux occurred for only 0.95 + 5.2/-1.2% of the time. Not every reflux event detected by a fall in pH was seen as an increase in counts as a result of reflux of food, and vice versa. This poor correlation of food and acid reflux implies incomplete mixing of food and acid in the stomach, and further shows the inadequacy of reflux diagnosis methods that depend on pH detection alone.Keywords
This publication has 20 references indexed in Scilit:
- A comparison of gastro‐oesophageal reflux in volunteers assessed by ambulatory pH and gamma monitoring after treatment with either Liquid Gaviscon or Algicon SuspensionAlimentary Pharmacology & Therapeutics, 1992
- Simultaneous esophageal pH monitoring and scintigraphy during the postprandial period in patients with severe reflux esophagitisDigestive Diseases and Sciences, 1991
- Gastric distribution and residence time of two anti-reflux formulationsInternational Journal of Pharmaceutics, 1987
- Evaluation of an enteric coated naproxen tablet using gamma scintigraphy and pH monitoringInternational Journal of Pharmaceutics, 1987
- Reproducibility of Gastroesophageal Reflux Scintigraphy and the Standard Acid Reflux TestScandinavian Journal of Gastroenterology, 1986
- In vitro tests overestimatein vivo neutralizing capacity of antacids in presence of foodDigestive Diseases and Sciences, 1985
- 99mTc-Labeled Solid-Phase MealJournal of Clinical Gastroenterology, 1983
- Effect of daily oral omeprazole on 24 hour intragastric acidity.BMJ, 1983
- Ambulatory monitoring of oesophageal pH in reflux oesophagitis using a portable radiotelemetry system.Gut, 1982
- A simple solid-phase marker for gastric emptying studiesThe British Journal of Radiology, 1982