Large Diameter Femoral Heads on Highly Cross-linked Polyethylene
- 1 June 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 447, 53-59
- https://doi.org/10.1097/01.blo.0000218742.61624.80
Abstract
Contemporary highly cross-linked polyethylenes have become the most widely used alternative bearing surfaces in total hip replacement and may be paired with large diameter femoral heads (> 32 mm) in patients considered to be at high risk for dislocation. We report on a prospective series of 42 patients (45 hips) who had total hip replacement using large diameter cobalt-chrome femoral heads articulating with a highly cross linked polyethylene after a minimum of 3 years followup (mean 3.3 years). At final followup, the final patient cohort showed excellent clinical results with no radiographic failures or episodes of loosening. There was no evidence of pelvic or femoral osteolysis. One patient sustained a dislocation due to a grossly malpositioned acetabular component necessitating early isolated acetabular revision. The average yearly steady state wear rate was -0.06 +/- 0.41 mm/year. The results of our short-term prospective series indicated total hip replacement with large femoral heads articulating with a highly cross linked polyethylene showed excellent wear characteristics and clinical results and could be considered in patients at increased risk for dislocation.Keywords
This publication has 25 references indexed in Scilit:
- In Vivo Comparative Wear Study of Traditional and Highly Cross-linked Polyethylene in Total Hip ArthroplastyThe Journal of Arthroplasty, 2005
- Range of Motion and Stability in Total Hip Arthroplasty With 28-, 32-, 38-, and 44-mm Femoral Head SizesThe Journal of Arthroplasty, 2005
- THE OTTO AUFRANC AWARD: Highly Cross-linked Polyethylene in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2004
- Biomechanics of Large Femoral HeadsPublished by Wolters Kluwer Health ,2004
- Metal-on-metal surface arthroplasty with a cemented femoral component*1A 7–10 year follow-up studyThe Journal of Arthroplasty, 2004
- Results of Reoperation for Hip DislocationPublished by Wolters Kluwer Health ,2004
- SHORT-TERM IN VIVO WEAR OF CROSS-LINKED POLYETHYLENEJournal of Bone and Joint Surgery, 2004
- Highly Cross-Linked Polyethylene in Cemented THAClinical Orthopaedics and Related Research, 2003
- COMPARISON OF THE WEAR RATES OF TWENTY-EIGHT AND THIRTY-TWO-MILLIMETER FEMORAL HEADS ON CROSS-LINKED POLYETHYLENE ACETABULAR CUPS IN A WEAR SIMULATORJournal of Bone and Joint Surgery, 2003
- A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical propertiesThe Journal of Arthroplasty, 2001