Assessment of cryoprecipitate‐thrombin solution for dural repair
- 1 November 1994
- journal article
- research article
- Published by Wiley in Head & Neck
- Vol. 16 (6) , 569-573
- https://doi.org/10.1002/hed.2880160612
Abstract
Background. After resection of cranial and skull base tumors, fibrin‐thrombin solutions can provide a temporary biologic seal of dural closures until final healing occurs. We investigated several variables affecting the strength of these „tissue glues”︁ for repair of dural defects using in vitro methods to model clinical repairs. Methods. The competence of human cryoprecipitate‐thrombin (CPT) „tissue glues”︁ in providing a watertight seal for patched rat fascia and human cadaveric dural defects was assessed. A saline column was fabricated to allow for controlled pressure (up to 700 mm) to be applied over an open aperature containing the repaired defect. Variables of repair included time after repair, defect size, and mixing temperature. Results. Wide variations in the strength of different cryoprecipitate glues were found. Time allowed after repair did not significantly affect the repair strength. Cooling the components of the glue solution prior to mixing significantly increased repair strength. Similar results were found for different defect sizes. Conclusions. Under controlled in vitro conditions, integrity of fibrin glue repairs varied widely. This was not attributable to differences in solution fibrinogen concentration. Cooling the „tissue glue”︁ components prior to mixing significantly increased repair strength of patched tissue defects.Keywords
This publication has 12 references indexed in Scilit:
- Experimental and Clinical Applications of Fibrin GluePlastic and Reconstructive Surgery, 1991
- The use of fibrin glue in intracranial procedures: Preliminary resultsThe Laryngoscope, 1990
- Neurosurgical Applications of Fibrin Glue: Augmentation of Dural Closure in 134 PatientsNeurosurgery, 1990
- Factors in the liquid portion of stored blood inhibit the proliferative response in mixed lymphocyte culturesTransfusion, 1988
- An autologous fibrinogen‐based adhesive for use in otologic surgeryTransfusion, 1988
- Autologous fibrin tissue adhesive: Factors influencing bonding powerThe Laryngoscope, 1988
- Compatibility of Autologous Fibrin Adhesive With Implant MaterialsJAMA Otolaryngology–Head & Neck Surgery, 1988
- Extended experimental and preliminary surgical findings with autologous fibrin tissue adhesive made from patient's own bloodThe Laryngoscope, 1986
- A Simple Autologous Fibrinogen Glue for Otologic SurgeryOtolaryngology -- Head and Neck Surgery, 1986
- Autologous fibrin tissue adhesiveThe Laryngoscope, 1985