Cyclic Melanotropins. VI. Reverse Phase HPLC Studies
- 1 May 1984
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 7 (6) , 1195-1210
- https://doi.org/10.1080/01483918408074037
Abstract
The chromatographic behavior of 17 cyclic melanocyte stimulating hormone (α-MSH, α-melanotropin) analogs were studied on two reversed phase columns (Altech and Vydac) using several mobile phases. It was observed that analogs which contain a D-amino acid were always eluted earlier than the corresponding L-amino acid-containing analogues. Substitution of penicillamine for cysteine in the 4 position led to a more lipophilic compound as expected, but when penicillamine was substituted in the 10 position, apparently a less lipophilic compound resulted. These observations can be interpreted as a result of a conformational change in the molecule caused by the particular substitution. Furthermore, decreasing the size of the intramolecular disulfide ring led to a decrease in lipophilicity (i.e. retention time). The carba modification of the disulfide bridge had a similar effect as previously seen in oxytocin and vasopressin, that is, a decrease in retention time.This publication has 15 references indexed in Scilit:
- THE SEPARATION OF PEPTIDE HORMONE DIASTEREOISOMERS BY REVERSE PHASE HIGH PRESSURE LIQUID CHROMATOGRAPHYInternational Journal of Peptide and Protein Research, 2009
- Structure-activity studies of highly potent cyclic [Cys4, Cys10]melanotropin analogsJournal of Medicinal Chemistry, 1983
- Amino acids and peptidesJournal of Chromatography A, 1983
- [half-Cys4,half-Cys10]-alpha-Melanocyte-stimulating hormone: a cyclic alpha-melanotropin exhibiting superagonist biological activity.Proceedings of the National Academy of Sciences, 1982
- Preparative Liquid Chromatographic Separation of Amino Acids and Peptides on Amberlite XAD-4Journal of Liquid Chromatography, 1982
- High-performance liquid chromatography of amino acids, peptides and proteins : XXXVI. Organic solvent modifier effects in the separation of unprotected peptides by reversed-phase liquid chromatographyJournal of Chromatography A, 1981
- Determination of the optical purity of amino acids by high-performance liquid chromatographyJournal of Chromatography A, 1981
- Separation of vasopressin analogues by reversed-phase high-performance liquid chromatographyJournal of Chromatography A, 1980
- Parameters affecting high performance liquid chromatographic separations of neurohypophyseal peptide hormonesAnalytical Chemistry, 1980
- Reverse Phase High Pressure Liquid Chromatography for the Separation of Peptide Hormone DiastereoisomersJournal of Chromatographic Science, 1978