Abstract
State-space averaging and linearization are applied to current-injected, constant-frequency switching regulators, resulting in a generalized two-loop system representation. The boost regulator is examined in detail to show that, as a theoretical goal, wide-bandwidth, first-order behavior can be achieved with no right-half-plane zeroes. Actual performance may be limited by switching frequency interference considerations.Keywords
This publication has 4 references indexed in Scilit:
- Measurement of Loop Gain with the Digital ModulatorIEEE Transactions on Power Electronics, 1986
- Simple switching control method changes power converter into a current sourcePublished by Institute of Electrical and Electronics Engineers (IEEE) ,1978
- A general unified approach to modelling switching-converter power stagesInternational Journal of Electronics, 1977
- Low-Frequency Characterization of Switched dc-dc ConvertersIEEE Transactions on Aerospace and Electronic Systems, 1973