Monitoring of sensory evoked potentials is highly reliable and helpful in the operating room
- 1 January 1987
- journal article
- review article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 3 (1) , 38-45
- https://doi.org/10.1007/bf00770882
Abstract
Because short-latency evoked potentials are relatively resistant to anesthetic agents, they can be used to monitor neural pathways during surgical procedures. The use of median nerve somatosensory evoked potentials to localize the central sulcus is an established aid of indisputable value in neurosurgical procedures involving cortical incisions for resection of certain epileptic foci, vascular malformations, or neoplasms near the central area of the brain. Likewise, recording of intraoperative nerve action potentials is currently regarded as indispensable in management of the neuroma-incontinuity after peripheral nerve trauma, as this evoked potential monitoring technique provides the only reliable method of distinguishing between axonotmetic and neurotmetic lesions. Evoked potential monitoring has been of value during many other types of surgical procedures, including cerebral aneurysm clipping, carotid endarterectomy, aortic procedures, microvascular decompression for trigeminal neuralgia and hemifacial spasm, acoustic neuroma resection, and a variety of spinal procedures. A detailed review of the literature is presented on the use of evoked potential monitoring for one of the more common indications: scoliosis surgery. Many orthopedic surgeons use the “wake-up test” only if the somatosensory evoked potentials change during surgery. A detailed review of the few reported cases of “false negative” evoked potentials is presented. The dearth of convincing reports of such phenomena in the face of so many positive experiences should persuade even the skeptical that monitoring of evoked potentials is a highly reliable and helpful intraoperative tool.Keywords
This publication has 42 references indexed in Scilit:
- False-Negative Results from Intraoperative SSEP'sJournal of Neurosurgery, 1986
- Limitations of Brain Stem Auditory Evoked Potentials for Intraoperative Monitoring during a Posterior Fossa Operation: Case Report and Technical NoteNeurosurgery, 1985
- Auditory brainstem evoked response as a hearing test in infants and children: A follow up studyJournal of Paediatrics and Child Health, 1985
- Intraoperative brain-stem auditory evoked potentials during posterior fossa microvascular decompressionJournal of Neurosurgery, 1985
- Relationship between hemispheric cerebral blood flow, central conduction time, and clinical grade in aneurysmal subarachnoid hemorrhageJournal of Neurosurgery, 1985
- Clinical Evaluation of Spinal Cord Monitoring in Scoliosis SurgerySpine, 1984
- Cortical Evoked Potential MonitoringSpine, 1984
- Operative management of selected brachial plexus lesionsJournal of Neurosurgery, 1983
- Intraoperative Loss of Somatosensory-evoked Potentials Predicts Loss of Spinal Cord FunctionAnesthesiology, 1982
- Evaluation of brainstem stroke using brainstem auditory evoked responses.Stroke, 1982