Management of Fluid Balance in CRRT: A Technical Approach
- 1 August 2005
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 28 (8) , 765-776
- https://doi.org/10.1177/039139880502800802
Abstract
Background: The possibility of making fluid balance errors during continuous renal replacement therapy has been identified since the beginning of this modality of treatment. The advent of automated machines has partially overcome this problem. Nevertheless, there are conditions and operation modes in which the potential for fluid balance errors is still present. Objective: To analyse fluid balance management in CRRT therapies across a range of currently marketed machine. Methods: The tests were conducted in vitro, utilizing saline solution for the blood circuit and regular dialysate/reinfusate for the dialysate/reinfusion circuit. The methodology used was based on the voluntary creation of a fluid balance error by altering the correct flow in the circuit of the different machines. Subsequently, the time for alarm occurrence and the threshold value for fluid balance error was evaluated. The alarm was overridden and the overall fluid error allowed by the machine was evaluated. Each machine was tested in conditions of different dialysate/filtrate flow rates and in different simulated treatment modalities. Results: Fluid balance errors can be easily avoided not only by a correct and careful adherence to the protocols of use of the current CRRT machines, but also by the compliance to prescriptions and programmed controls during therapy. Most importantly, if an alarm appears on the machine, one can try to override it without major problems; major problems may occur when multiple override commands are operated without identifying the problem and solving it adequately. Conclusion: Machines seem to be designed with adequate safety features and accurate alarm systems. However, features and alarms can be manipulated by operators creating the opportunity for serious error. Physicians and nurses involved in prescription and delivery of CRRT should have precise protocols and defined procedures in relation to machine alarms to prevent major clinical problems.Keywords
This publication has 15 references indexed in Scilit:
- Acute Renal Failure in Critically Ill PatientsA Multinational, Multicenter StudyJAMA, 2005
- Estimating the impact of renal replacement therapy choice on outcome in severe acute renal failureClinical Nephrology, 2005
- Continuous renal replacement therapy improves renal recovery from acute renal failureCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2005
- Basic principles and practical steps in the management of fluid balance in the newbornSeminars in Neonatology, 2003
- The Acute Dialysis Quality Initiative—Part VII: Fluid composition and management in CRRTAdvances in Renal Replacement Therapy, 2002
- The Acute Dialysis Quality Initiative—Part V: Operational characteristics of CRRTAdvances in Renal Replacement Therapy, 2002
- A technique for the monitoring of blood flow during continuous haemofiltrationIntensive Care Medicine, 2002
- Fluid Management in CRRTPublished by S. Karger AG ,2001
- Effects of different doses in continuous veno-venous haemofiltration on outcomes of acute renal failure: a prospective randomised trialThe Lancet, 2000
- Management of Acute Renal Failure in the Critically Ill with Continuous Venovenous HemodiafiltrationRenal Failure, 1992