Sealed Position Sensitive Hard X-Ray Detector Having Large Drift Region for All Sky Camera with High Angular Resolution
- 1 January 1979
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 26 (1) , 502-505
- https://doi.org/10.1109/TNS.1979.4329681
Abstract
A sealed position sensitive proportional counter filled with two atmospheres of 95% xenon and 5% methane, and containing a drift region of 24 atm cm, has operated in a stable manner for many months. The detector contains G-10 frames to support the anode and cathode wires. The detector was sealed successfully by a combination of vacuum baking the G-10 frames at 150°C for two weeks followed by assembly into the detector in an environment of dry nitrogen, and the use of passive internal getters. The counter is intended for use with a circumferential cylindrical collimator containing many random slit openings. Together they provide a very broad field of view detection system with the ability to locate cosmic hard X-ray and soft gamma ray sources to an angular precision of a minute of arc. A set of instruments based on this principle have been proposed for satellites to detect and precisely locate cosmic gamma ray bursts.Keywords
This publication has 4 references indexed in Scilit:
- Electronic Discrimination of the Effective Thickness of Proportional CountersIEEE Transactions on Nuclear Science, 1977
- Localization of gamma-ray bursts with wide field multiple pinhole camera system in near earth orbitAstrophysics and Space Science, 1976
- Observations of Gamma-Ray Bursts of Cosmic OriginThe Astrophysical Journal, 1973
- Proportional Counter Photon CameraIEEE Transactions on Nuclear Science, 1972