Xenon computed tomography measuring cerebral blood flow in the determination of brain death in children
- 1 June 1989
- journal article
- research article
- Published by Wiley in Annals of Neurology
- Vol. 25 (6) , 539-546
- https://doi.org/10.1002/ana.410250603
Abstract
Local cerebral blood flow was measured using stable xenon computed tomography in 21 children, 10 of whom were clinically brain dead and had electrocerebral silence as determined by electroencephalography. Radioisotopic brain scanning in 9 patients showed no visible cerebral activity in all patients and minimal residual sagittal sinus activity in 4. In this population, mean cerebral blood flow as measured by xenon computed tomography was 1.3 ± 1.6 ml/min/100 gm. Respiratory support was discontinued in 8 patients, and 2 patients had cardiac arrest. Eleven profoundly comatose children who did not meet all clinical criteria for brain death and who had markedly suppressed but not isoelectric electroencephalograms had an average cerebral blood flow of 33.5 ± 16.3 ml/min/100 gm as determined by xenon computed tomography. Flows in this group ranged from 11.8 ± 4.1 to 62.3 ± 1.9 ml/min/100 gm. There was no difference in cerebral blood flow in those children who survived (30.4 ± 16.3 ml/min/100 gm; n = 7) compared with those who died acutely (38.3 ± 14.3 ml/min/100 gm; n = 4). Two patients who survived had average total flows of only 11.8 and 12.1 ml/min/100 gm. Our findings suggest that in infants and children older than 1 month, (1) cerebral blood flow below approximately 10 ml/min/100 gm is consistent with clinical brain death, (2) cerebral blood flow of less than 5 ml/min/100 gm is consistent with no flow as demonstrated by radionuclide techniques, and (3) flow of more than 10 to 15 ml/min/100 gm is associated with the potential for survival.This publication has 28 references indexed in Scilit:
- Guidelines for the determination of brain death in childrenAnnals of Neurology, 1987
- Brainstem death with persistent EEG activityCritical Care Medicine, 1987
- Errors in cerebral blood flow determinations by xenon‐enhanced computed tomography due to estimation of arterial xenon concentrationsMedical Physics, 1987
- Can raising cerebral blood flow improve outcome after acute cerebral infarction?Stroke, 1987
- Brain death in children: Part IPediatric Neurology, 1987
- Local Cerebral Blood Flow Alterations (Xe-CT Method) in an Accident VictimJournal of Computer Assisted Tomography, 1984
- Clinical experience with the use of xenon-enhanced CT blood flow mapping in cerebral vascular disease.Stroke, 1984
- Progress in cerebrovascular disease: local cerebral blood flow by xenon enhanced CT.Stroke, 1982
- Differential regional vulnerability in transient focal cerebral ischemia.Stroke, 1982
- Regulation of local cerebral blood flow in normal and hypoxic newborn dogsAnnals of Neurology, 1982