Optimal atrioventricular delay at rest and during exercise in patients with dual chamber pacemakers: a non-invasive assessment by continuous wave Doppler.
Open Access
- 1 February 1989
- Vol. 61 (2) , 161-166
- https://doi.org/10.1136/hrt.61.2.161
Abstract
The optimal atrioventricular delay at rest and during exercise was investigated in nine patients with heart block and implanted dual chamber pacemakers. All patients studied had normal left ventricular function and a normal sinus node rate response to exercise. Cardiac output was measured by continuous wave Doppler and was calculated as the product of stroke distance measured by Doppler at the left ventricular outflow, aortic root area measured by M mode echocardiography, and heart rate. Pacemakers were programmed in the DDD mode. Cardiac output was measured with the patient at rest while supine and while erect and at the peak of submaximal exercise (the end of stage 1 of the Bruce protocol) with the pacemakers programmed to the following atrioventricular intervals: 75-80 ms, 100-110 ms, 140-150 ms, and 200 ms. During exercise the basic pacing rate was programmed to 70 beats/min. Cardiac output at rest while supine and erect was greatest with an atrioventricular delay of 140-150 ms and it was significantly higher than that with an atrioventricular delay of 75-80 ms. On average there was a 31% decrease in cardiac output when patients stood up. During treadmill exercise, however, cardiac output was greatest when the atrioventricular delay was 75-80 ms, and this was significantly higher than the cardiac output with atrioventricular delays of 150 and 200 ms. During exercise 1:1 atrioventricular relations were maintained in patients at all atrioventricular intervals. In patients with atrioventricular sequential pacemakers cardiac output at rest is greatest with an atrioventricular delay of 140-150 ms but during exercise the optimal atrioventricular delay is shorter. Rate modulation of the atrioventricular interval may improve the haemodynamic response and possibly exercise tolerance in patients with dual chamber pacemakers.This publication has 27 references indexed in Scilit:
- Usefulness of noninvasive doppler measurement of ascending aortic blood velocity and acceleration in detecting impairment of the left ventricular functional response to exercise three weeks after acute myocardial infarctionThe American Journal of Cardiology, 1986
- Evaluation by pulsed doppler echocardiography of the atrial contribution to left ventricular filling in patients with DDD pacemakersThe American Journal of Cardiology, 1986
- Hemodynamic comparison of ventricular pacing, atrioventricular sequential pacing, and atrial synchronous ventricular pacing using radionuclide ventriculographyThe American Journal of Cardiology, 1986
- Doppler ultrasound measurement of cardiac output in patients with physiologic pacemakersThe American Journal of Cardiology, 1984
- Evaluation of left ventricular performance by radionuclide ventriculography in patients with atrioventricular versus ventricular demand pacemakersAmerican Heart Journal, 1984
- The mechanism of closure of the mitral valve: a continuing controversy.Circulation, 1979
- Hemodynamic benefits of atrioventricular sequential pacing after cardiac surgeryThe American Journal of Cardiology, 1977
- A comparison of the hemodynamic effects of ventricular and sequential A-V pacing in patients with heart blockAmerican Heart Journal, 1969
- Re-evaluation of the atrial contribution to ventricular functionThe American Journal of Cardiology, 1968
- Atrial contribution to cardiac output in complete heart blockThe American Journal of Cardiology, 1965