Polyp Volume Versus Linear Size Measurements at CT Colonography: Implications for Noninvasive Surveillance of Unresected Colorectal Lesions
- 1 June 2006
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 186 (6) , 1605-1610
- https://doi.org/10.2214/ajr.05.0760
Abstract
OBJECTIVE. Proposed surveillance of unresected medium-sized (6.0-9.9 mm) polyps will require reliable detection of small incremental changes. The purpose of this study was to assess the reproducibility of linear versus volume measurements of polyp size at CT colonography (CTC) and to correlate results with a hemispheric model. MATERIALS AND METHODS. The study group consisted of 30 polyps on supine and prone CTC data sets. Measurements were performed separately by two experienced radiologists using the same CTC system (Vitrea 2), resulting in 120 linear and volume measurements. Linear size was defined as the longest dimension among the 2D multiplanar reconstruction views. Semiautomated volume determination required manual tracing of polyp boundaries on 2D multiplanar reconstruction views. The relative error between reviewers 1 and 2 was defined as 100 × (|D1 - D2|)/Dave for linear size (D) and as 100 × (|V1 - V2)/Vave for volume (V), where ave is average. RESULTS. The mean relative error for linear size and volume measurement was 10.4% ± 10.7% and 16.9% ± 13.2%, respectively. Median linear size and volume of polyps were 9.4 mm and 270 mm3, respectively. CTC-derived volumes for medium-sized polyps closely approximated hemispheric volume (V= (π/12) × Db, where b =3.13, r2 = 0.90). Small incremental changes in hemispheric size result in a 3:1 relative change in volume versus diameter, such that a 1-mm diameter change in a medium-sized hemispheric polyp results in a relative change in linear size and volume ranging from approximately 11-18% and 31-53%, respectively. CONCLUSION. Because changes in polyp volume are amplified compared with linear dimension, volume measurement rather than diameter measurement will better allow detection of small incremental changes in polyp size using CTC.Keywords
This publication has 26 references indexed in Scilit:
- Radiologic Assessment of Rectosigmoid Cancer Before and After Neoadjuvant Radiation Therapy: Comparison Between Quantitation TechniquesAmerican Journal of Roentgenology, 2005
- Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic AdultsNew England Journal of Medicine, 2003
- Virtual Colonoscopy for Colon Cancer Screening: Further Reflections on Polyps and PoliticsAmerican Journal of Roentgenology, 2003
- ESTIMATION OR QUANTIFICATION OF TUMOUR VOLUME?. CT study on irregular phantomsActa Radiologica, 2001
- New Guidelines to Evaluate the Response to Treatment in Solid TumorsJNCI Journal of the National Cancer Institute, 2000
- Factors Influencing the Accuracy of Volume Measurements in Spiral CT: A Phantom StudyJournal of Computer Assisted Tomography, 1997
- The Impact of 2D Versus 3D Quantitation of Tumor Bulk Determination on Current Methods of Assessing Response to TreatmentJournal of Computer Assisted Tomography, 1996
- Analysis of interobserver and intraobserver variability in CT tumor measurements.American Journal of Roentgenology, 1996
- Accuracy of Volume Measurements of Computed Tomography and Magnetic Resonance Imaging Phantoms by Three-Dimensional Reconstruction and Preliminary Clinical ApplicationInvestigative Radiology, 1994
- Volume determinations using computed tomographyAmerican Journal of Roentgenology, 1982