Site-Specific in vivo Targeting of Magnetoliposomes Using Externally Applied Magnetic Field
Open Access
- 1 April 2000
- journal article
- research article
- Published by Walter de Gruyter GmbH in Zeitschrift für Naturforschung C
- Vol. 55 (3-4) , 278-281
- https://doi.org/10.1515/znc-2000-3-422
Abstract
Human serum albumin labeled with technetium-99m was encapsulated together with magnetite particles into phosphatidylcholine/cholesterol liposomes. In order to investigate the stability of this complex and its ability to be used for magnetic drug targeting, the in-vivo distribution after intravenous administration in rats was estimated. For in-vivo targeting an SmCo permanent magnet with intensity ~ 0.3 5 T was attached near the right kidney. Difference between the relative radioactivity in the magnetically targeted right kidney (25.92±5.84%) and non-targeted left kidney (0.93±0.05%) is sufficiently high for relevant clinical applications.Keywords
This publication has 0 references indexed in Scilit: