Stem cement debonding is 1 of the most common forms of fixation failure and is thought to be a prelude to gross loosening of a total hip reconstruction. However, the immediate consequences of debonding remains a matter of controversy. The dynamic effects of stem cement debonding in total hip reconstruction were analyzed using 3-dimensional finite element techniques. Stem cement interface conditions were assumed as completely bonded or unbonded, with or without friction. The dynamic effects were accounted for, as presented by the stance and swing phases of the gait cycle. It was found that both cyclic micromotions at the stem cement interface and stresses in the cement mantle were effectively reduced by friction. The friction cases produced failure probabilities of the cement mantle that were relatively close to the one generated by the bonded stem. The probability of mechanical failure of the cement bone interface decreased after debonding and decreased more with reduced stem cement friction. These results show that, although a firm and lasting bond between stem and cement may be desirable for preventing cement failure, the mechanical effects of a debonded stem are less detrimental than were assumed earlier. For straight tapered stem shapes subjected to the loading conditions described, a polished stem may be desirable for the cement bone interface mechanics.This publication has 21 references indexed in Scilit:
- Failure of the cement-bone interface. A consequence of strengthening the cement-prosthesis interface?The Journal of Bone and Joint Surgery. British volume, 1994
- Hip joint loading during walking and running, measured in two patientsJournal of Biomechanics, 1993
- A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip componentsJournal of Biomechanics, 1991
- Micromotion of cemented and uncemented femoral componentsThe Journal of Bone and Joint Surgery. British volume, 1991
- Comparison of the fatigue characteristics of centrifuged and uncentrifuged simplex P bone cementJournal of Orthopaedic Research, 1987
- Tensile Fatigue Failure of Acrylic Bone CementJournal of Biomechanical Engineering, 1983
- Cement strain measurement surrounding loose and well‐fixed femoral component stemsJournal of Biomedical Materials Research, 1983
- A physiologically based criterion of muscle force prediction in locomotionJournal of Biomechanics, 1981
- A three-dimensional biomechanical model of hip musculatureJournal of Biomechanics, 1981
- The Brittle Strength of Orthotropic MaterialsJournal of Composite Materials, 1967