Abstract
Background— A relatively simple, invasive method for quantitatively assessing the status of the coronary microcirculation independent of the epicardial artery is lacking. Methods and Results— By using a coronary pressure wire and modified software, it is possible to calculate the mean transit time of room-temperature saline injected down a coronary artery. The inverse of the hyperemic mean transit time has been shown to correlate with absolute flow. We hypothesize that distal coronary pressure divided by the inverse of the hyperemic mean transit time provides an index of microcirculatory resistance (IMR) that will correlate with true microcirculatory resistance (TMR), defined as the distal left anterior descending (LAD) pressure divided by hyperemic flow, measured with an external ultrasonic flow probe. A total of 61 measurements were made in 9 Yorkshire swine at baseline and after disruption of the coronary microcirculation, both with and without an epicardial LAD stenosis. The mean IMR (16.9±6.5 U to 25.9±14.4 U, P =0.002) and TMR (0.51±0.14 to 0.79±0.32 mm Hg · mL −1 · min −1 , P =0.0001), as well as the % change in IMR (147±66%) and TMR (159±105%, P =NS versus IMR % change), increased significantly and to a similar degree after disruption of the microcirculation. These changes were independent of the status of the epicardial artery. There was a significant correlation between mean IMR and TMR values, as well as between the % change in IMR and % change in TMR. Conclusion— Measuring IMR may provide a simple, quantitative, invasive assessment of the coronary microcirculation.Keywords
This publication has 6 references indexed in Scilit:
- Prognostic significance of elevated troponin i after percutaneous coronary interventionJournal of the American College of Cardiology, 2002
- Myocardial Dysfunction With Coronary MicroembolizationCirculation Research, 2002
- Evaluation of a transit-time system for the chronic measurement of blood flow in conscious sheepJournal of Applied Physiology, 1995
- Reduced Coronary Vasodilator Function in Infarcted and Normal Myocardium after Myocardial InfarctionNew England Journal of Medicine, 1994
- Lack of myocardial perfusion immediately after successful thrombolysis. A predictor of poor recovery of left ventricular function in anterior myocardial infarction.Circulation, 1992