Sialolithiasis: MR Sialography of the Submandibular Duct—An Alternative to Conventional Sialography and US?
- 1 September 2000
- journal article
- clinical trial
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 216 (3) , 665-671
- https://doi.org/10.1148/radiology.216.3.r00se12665
Abstract
To determine the value of magnetic resonance (MR) sialography for the diagnosis of sialolithiasis by comparing results prospectively with those of ultrasonography (US) and digital sialography. MR sialography was prospectively performed with T2-weighted three-dimensional (3D) constructive interference in steady-state (CISS) and rapid acquisition with relaxation-enhancement (RARE) sequences in 24 patients suspected of having sialolithiasis. Evoked salivation was used as contrast material. T1-weighted spin-echo and T2-weighted turbo spin-echo MR imaging also were performed. The results were then compared with those of US and digital sialography, with the latter as standard of reference. The 3D CISS images were significantly (P: <.05) superior to RARE images for demonstrating the submandibular ductal system, followed by T2-weighted turbo spin-echo images (P: <.01) and T1-weighted spin-echo images (P: <.001). The sensitivity and specificity were 100% and 80%, respectively, for CISS MR sialography and 80% and 100%, respectively, for RARE MR imaging. The sensitivity and specificity of US were both 80%. MR sialography with evoked salivation is noninvasive and allows delineation of the submandibular ductal system and detection of sialoliths with accuracy that is similar to that of digital sialography and superior to that of US.Keywords
This publication has 15 references indexed in Scilit:
- Sonography, CT, CT sialography, MRI and MRI sialography in investigation of the facial nerve and the differentiation between deep and superficial parotid lesionsNeuroradiology, 1997
- Ultrafast Computed Tomography and Three-Dimensional Image Processing of CT Sialography in Patients with Parotid Masses Poorly Defined by Magnetic Resonance ImagingActa Oto-Laryngologica, 1996
- Internal architecture of the parotid gland at MR imaging: facial nerve or ductal system?Radiology, 1993
- An adverse reaction following sialography.Dento maxillo facial radiology, 1993
- Wertigkeit der digitalen Subtraktionssialographie im Vergleich mit konventioneller Sialographie, Speicheldrüsensonographie und OperationsbefundRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1992
- Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid.Radiology, 1990
- Sonography of the salivary glandsAmerican Journal of Roentgenology, 1989
- Der Wert von Sonographie und Sialographie in der Diagnostik von SpeicheldrüsenerkrankungenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1987
- RARE imaging: A fast imaging method for clinical MRMagnetic Resonance in Medicine, 1986
- The normal sialogramOral Surgery, Oral Medicine, Oral Pathology, 1968