Rapid screening and characterization of drug metabolites using a new quadrupole–linear ion trap mass spectrometer
Open Access
- 9 January 2003
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 38 (2) , 138-150
- https://doi.org/10.1002/jms.420
Abstract
The application of a new hybrid RF/DC quadrupole–linear ion trap mass spectrometer to support drug metabolism and pharmacokinetic studies is described. The instrument is based on a quadrupole ion path and is capable of conventional tandem mass spectrometry (MS/MS) as well as several high‐sensitivity ion trap MS scans using the final quadrupole as a linear ion trap. Several pharmaceutical compounds, including trocade, remikiren and tolcapone, were used to evaluate the capabilities of the system with positive and negative turbo ionspray, using either information‐dependent data acquisition (IDA) or targeted analysis for the screening, identification and quantification of metabolites. Owing to the MS/MS in‐space configuration, quadrupole‐like CID spectra with ion trap sensitivity can be obtained without the classical low mass cutoff of 3D ion traps. The system also has MS3 capability which allows fragmentation cascades to be followed. The combination of constant neutral loss or precursor ion scan with the enhanced product ion scan was found to be very selective for identifying metabolites at the picogram level in very complex matrices. Owing to the very high cycle time and, depending on the mass range, up to eight different MS experiments could be performed simultaneously without compromising chromatographic performance. Targeted product ion analysis was found to be complementary to IDA, in particular for very low concentrations. Comparable sensitivity was found in enhanced product ion scan and selected reaction monitoring modes. The instrument is particularly suitable for both qualitative and quantitative analysis. Copyright © 2003 John Wiley & Sons, Ltd.Keywords
This publication has 14 references indexed in Scilit:
- A two-dimensional quadrupole ion trap mass spectrometerPublished by American Chemical Society (ACS) ,2002
- A new linear ion trap mass spectrometerRapid Communications in Mass Spectrometry, 2002
- Peer Reviewed: Systematic LC/MS Metabolite Identification in Drug DiscoveryAnalytical Chemistry, 2001
- Chemical Image Fusion. The Synergy of FT-NIR and Raman Mapping Microscopy To Enable a More Complete Visualization of Pharmaceutical FormulationsAnalytical Chemistry, 2001
- The synthesis of labelled forms of cipemastatJournal of Labelled Compounds and Radiopharmaceuticals, 2001
- The impact of accurate mass measurements using quadrupole/time-of-flight mass spectrometry on the characterisation and screeningAnalusis, 2000
- Review of the 48th ASMS Conference on mass spectrometry and allied topics held in Long Beach, California June 11–15, 2000Journal of the American Society for Mass Spectrometry, 2000
- Metabolism and excretion of tolcapone, a novel inhibitor of catechol‐O‐methyltransferaseBritish Journal of Clinical Pharmacology, 1999
- Excretion and metabolism of remikiren, a potent orally active inhibitor of primate reninXenobiotica, 1996
- Ion spray mass spectrometric detection for liquid chromatography: A concentration- or a mass-flow-sensitive device?Journal of Chromatography A, 1993