Clinical Investigation of a New Dual‐Chamber Implantable Cardioverter Defibrillator with Improved Rhythm Discrimination Capabilities
- 1 February 2003
- journal article
- clinical trial
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 14 (2) , 144-149
- https://doi.org/10.1046/j.1540-8167.2003.02285.x
Abstract
Despite continuing advances, inappropriate implantable cardioverter defibrillator (ICD) therapies in response to nonventricular tachyarrhythmias continue to cause patient discomfort and increased follow-up demands. We investigated the performance of a new dual-chamber ICD (Photon DR, St. Jude Medical), with specific attention to its arrhythmia discrimination and detection capabilities. The system uses a hierarchical approach to tachyarrhythmia classification utilizing a new AV Rate Branch feature and subsequently utilizing morphology analysis, onset, and stability criteria. The arrhythmia discrimination results from this study group were compared to historical control group data from a recent clinical investigation of single-chamber Contour MD (Morphology Discrimination) and Angstrom MD ICDs without the Rate Branch feature. Rhythm discrimination was evaluated by comparing ventricular tachycardia diagnosis sensitivity and specificity between the two groups. To determine whether the new discrimination scheme affected detection speed, median ventricular fibrillation (VF) detection and redetection times also were compared. The study group consisted of 107 patients, and the control group consisted of 161 patients. Use of the AV Rate Branch feature was associated with significant improvements in both sensitivity (100% vs 97.9%, P < 0.0001) and specificity (84% vs 55.7%, P = 0.0002) of ventricular tachycardia diagnosis. Use of the new scheme slightly but significantly accelerated VF detection times (2.8 vs 3.0 sec, P < 0.0001) and redetection times (1.3 vs 1.4 sec, P < 0.0001). Adverse events were typical for this patient population. Compared with earlier St. Jude Medical ICDs, the Photon DR ICD offers improved rhythm discrimination without compromising VF detection time.Keywords
This publication has 13 references indexed in Scilit:
- Critical Analysis of Dual-Chamber Implantable Cardioverter-Defibrillator Arrhythmia DetectionCirculation, 2001
- Inappropriate therapy from atrial fibrillation and sinus tachycardia in automated implantable cardioverter defibrillatorsAmerican Heart Journal, 2000
- Clinical Experience with the New Detection Algorithms for Atrial Fibrillation of a Defibrillator with Dual Chamber Sensing and PacingJournal of Cardiovascular Electrophysiology, 1999
- Prevention of Implantable-Defibrillator Shocks by Treatment with SotalolNew England Journal of Medicine, 1999
- Is inappropriate therapy a resolved issue with current implantable cardioverter defibrillators?The American Journal of Cardiology, 1999
- Adverse Events With Transvenous Implantable Cardioverter-DefibrillatorsCirculation, 1998
- Prospective Evaluation of New and Old Criteria to Discriminate Between Supraventricular and Ventricular Tachycardia in Implantable DefibrillatorsPacing and Clinical Electrophysiology, 1998
- Performance of Basic Ventricular Tachycardia Detection Algorithms in Implantable Cardioverter Defibrillators; Implications for Device ProgrammingPacing and Clinical Electrophysiology, 1997
- Limitations and Late Complications of Third-Generation Automatic Cardioverter-DefibrillatorsCirculation, 1995
- Electrocardiographically Documented Unnecessary, Spontaneous Shocks in 241 Patients With Implantable Cardioverter DefibrillatorsPacing and Clinical Electrophysiology, 1992