Eddy current correction in diffusion‐weighted imaging using pairs of images acquired with opposite diffusion gradient polarity
Open Access
- 29 December 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (1) , 188-193
- https://doi.org/10.1002/mrm.10690
Abstract
In echo‐planar‐based diffusion‐weighted imaging (DWI) and diffusion tensor imaging (DTI), the evaluation of diffusion parameters such as apparent diffusion coefficients and anisotropy indices is affected by image distortions that arise from residual eddy currents produced by the diffusion‐sensitizing gradients. Correction methods that coregister diffusion‐weighted and non‐diffusion‐weighted images suffer from the different contrast properties inherent in these image types. Here, a postprocessing correction scheme is introduced that makes use of the inverse characteristics of distortions generated by gradients with reversed polarity. In this approach, only diffusion‐weighted images with identical contrast are included for correction. That is, non‐diffusion‐weighted images are not needed as a reference for registration. Furthermore, the acquisition of an additional dataset with moderate diffusion‐weighting as suggested by Haselgrove and Moore (Magn Reson Med 1996;36:960–964) is not required. With phantom data it is shown that the theoretically expected symmetry of distortions is preserved in the images to a very high degree, demonstrating the practicality of the new method. Results from human brain images are also presented. Magn Reson Med 51:188–193, 2004.Keywords
This publication has 21 references indexed in Scilit:
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002
- High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneityMagnetic Resonance in Medicine, 2002
- Detection and modeling of non‐Gaussian apparent diffusion coefficient profiles in human brain dataMagnetic Resonance in Medicine, 2002
- Condition Number as a Measure of Noise Performance of Diffusion Tensor Data Acquisition Schemes with MRIJournal of Magnetic Resonance, 2000
- Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imagingMagnetic Resonance in Medicine, 1999
- A Comparative Study of Acquisition Schemes for Diffusion Tensor Imaging Using MRIJournal of Magnetic Resonance, 1999
- Optimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brainMagnetic Resonance Imaging, 1997
- Correction for distortion of echo‐planar images used to calculate the apparent diffusion coefficientMagnetic Resonance in Medicine, 1996
- Self-Compensating Pulsed Magnetic-Field Gradients for Short Recovery TimesJournal of Magnetic Resonance, Series A, 1994
- A simple method for obtaining cross‐term‐free images for diffusion anisotropy studies in NMR microimagingMagnetic Resonance in Medicine, 1991