Gastroesophageal pH step-up inaccurately locates proximal border of lower esophageal sphincter
- 1 August 1992
- journal article
- research article
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 37 (8) , 1185-1191
- https://doi.org/10.1007/bf01296558
Abstract
Limiting the widespread use of 24-hr pH monitoring is the necessity of manometrically placing the pH probe 5 cm above the proximal lower esophageal sphincter (LES) border. Therefore, we prospectively compared LES localization by gastroesophageal pH step-up with manometry in 71 patients and 14 asymptomatic volunteers. The gastroesophageal pH step-up significantly correlated with the proximal LES border in patients (r=0.53, P<0.0001) and volunteers (r=0.91, P<0.0001). Based on previously published criteria, the pH step-up value was considered acceptably accurate if it was within ±3 cm (6 cm total span) of the manometrically determined proximal LES border. In 58% of patients and 29% of volunteers the pH step-up occurred outside this accuracy range. Esophagitis (P=0.015) and abnormal reflux parameters (P=0.002) were variables contributing to this error. Subsequent analysis found that the pH step-up overestimated the proximal LES border and occurred at the midportion of the sphincter. The pH step-up still inaccurately located the mid LES in 34% of patients. Therefore, manometry should remain the standard for accurate LES localization prior to placing the pH probe.Keywords
This publication has 12 references indexed in Scilit:
- ESOPHAGEAL 24-H PH MONITORING - IS PRIOR MANOMETRY NECESSARY FOR CORRECT POSITIONING OF THE ELECTRODE1990
- Extended four-channel esophageal pH monitoring: The importance of acid reflux patterns at the middle and proximal levelsJournal of Pediatric Surgery, 1988
- The lower esophageal sphincter in health and diseaseThe American Journal of Surgery, 1988
- Simultaneous pH Recordings from Multiple Esophageal Sites in Children with and without Distal Gastroesophageal RefluxJournal of Pediatric Gastroenterology and Nutrition, 1988
- Ambulatory 24-Hour Esophageal pH MonitoringJournal of Clinical Gastroenterology, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Gastric Secretion and Reflux Pattern in Reflux Oesophagitis before and during Ranitidine TreatmentScandinavian Journal of Gastroenterology, 1986
- Gastroesophageal RefluxAnnals of Internal Medicine, 1982
- The distal esophageal sphincter and its relationship to gastroesophageal refluxJournal of Surgical Research, 1974
- Prolonged pH recording in the study of Gastro-oesophageal refluxBritish Journal of Surgery, 1969