The Importance of Multidirectional Motion on the Wear of Polyethylene
- 1 September 1996
- journal article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 210 (3) , 157-165
- https://doi.org/10.1243/pime_proc_1996_210_408_02
Abstract
The development of a new hip simulator for the study of bearing materials used in total hip replacements has led to several findings which add important new information to the understanding of wear process of ultra-high molecular weight polyethylene, the most commonly used bearing material today for total joint replacements. Using this hip simulator which is capable of applying the physiological motion pathways occurring during gait to total hip components which are held in the correct anatomical position under the complex loading conditions of the hip in gait, the authors have shown that physiological motion pathways produce very different wear rates and morphology of the wear surface than unidirectional reciprocating pathways. Scanning electron microscopy studies show striking differences in the morphology of the wear surfaces of the polyethylene depending upon the relative motions of the components. Wear rates, surface morphology and particle debris generation consistent with clinical and retrieved studies are achieved when physiological conditions are simulated.Keywords
This publication has 29 references indexed in Scilit:
- Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissuesJournal of Biomedical Materials Research, 1995
- Hip joint loading during walking and running, measured in two patientsJournal of Biomechanics, 1993
- A Simulator Study of Friction in Total Replacement Hip JointsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1992
- Design and Development of a Versatile Hip Joint Simulator and a Preliminary Assessment of Wear and Creep in Charnley Total Replacement Hip JointsEngineering in Medicine, 1988
- An Evaluation of Retrieved UHMWPE Hip Joint CupsJournal of Biomaterials Applications, 1988
- Formation of a synovial‐like membrane at the bone‐cement interface: Its role in bone resorption and implant loosening after total hip replacementArthritis & Rheumatism, 1986
- The appearances of wear on polyethylene—a comparison of in vivo and in vitro wear surfacesJournal of Biomedical Materials Research, 1978
- Rate of Wear in Total Hip ReplacementClinical Orthopaedics and Related Research, 1975
- A simulator for load bearing jointsWear, 1972
- Measurement of Hip-Joint Motion during WalkingJournal of Bone and Joint Surgery, 1969